Quiz

Note: We are not providing answers to the questions because many schools and other study programs are using the same questions for determining course grades.

1. A conduit threading die is used for which of the following reasons?

  1. To thread conduit over 1 -inch diameter only
  2. To make a tapered thread on conduit
  3. To thread and cut conduit in one operation

2. The solvent-welding technique for joining PVC conduit is superior because the finished joints are _____.

  1. waterproof and vapor proof
  2. explosion proof
  3. corrosion resistant

3. What number of 90-degree bends are permitted in a run of conduit?

  1. One
  2. Two
  3. Five
  4. Four

4. What type of bender makes a full 90-degree bend in conduit with a single motion?

  1. Sweep
  2. Hickey
  3. Field
  4. One-shot

5. The distance from the back of a 90- degree bend to the end of the conduit is referred to by what term?

  1. Stub-up
  2. Radius
  3. Take-up
  4. Offset measurement

6. Two adjacent 90-degree bends in the same conduit make up what type of bend?

  1. Box-offset
  2. Double-right-angle
  3. Double-offset
  4. Back-to-back

7. Offset bends are used to avoid contacting a part of the structure or to bring the conduit out from the structure to match a knockout in a box or panel.

  1. True
  2. False

8. The practice of taking small bites to reduce kinking or crimping should be used when you are bending with what type of bender?

  1. One-shot
  2. EMT
  3. Hickey
  4. Hydraulic

9. Generally, what is the smallest size raceway that can be installed?

  1. 1/4 in.
  2. 3/8 in.
  3. 1/2 in.
  4. 3/4 in.

10. EMT and IMC conduit must be supported (a) within how many feet of each box and (b) at intervals of how many feet thereafter?

  1. (a) 5 (b) 10
  2. (a) 5 (b) 6
  3. (a) 3 (b) 10
  4. (a) 3 (b) 6

11. Flexible metal conduit must be supported within how many inches of each box or fitting?

  1.  12
  2.  18
  3.  24
  4.  36

12. An electrician finds that a run of conduit between boxes will have five 90- degree bends. What, if anything, should the electrician do to complete the conduit run?

  1. Use a concealed Condulet
  2. Increase the radius of each bend
  3. Use a Condulet instead of one of the bends
  4. Nothing

13. According to the NEC�, the bends in one conduit run cannot exceed how many degrees?

  1. 120�
  2. 240�
  3. 300�
  4. 360�

14. Which of the following tools is/are required to restore a hook on the end of a fish tape?

  1. A set of vise grips
  2. A vise and pair of pliers
  3. A pair of longnose pliers and a pair of side-cutting pliers
  4. A pair of pliers and a torch

15. What advantage is there when you pull conductors from the second floor of a structure to the first floor?

  1. A fish tape is not required
  2. The weight of the wires helps in the pull
  3. The task only requires one person

16. Which of the following tools makes a good handle for pulling a fish tape?

  1. Hammer
  2. Side-cutting pliers
  3. Adjustable wrench
  4. Open-end wrench

17. What condition occurs when too many conductors have been installed in the conduit?

  1. The power factor improves
  2. The smaller conductors ampacity improves
  3. Overheating occurs and the conductor ampacity decreases
  4. Overheating occurs and the conductor ampacity increases