2-2 MAINTENANCE PROCEDURES FOR AUTOMOTIVE BATTERIES
PREVENTIVE MAINTENANCE
In nearly all cases of early failure of automotive batteries, the cause can be traced to a lack of preventive maintenance. When given proper care, batteries generally will give no trouble until they are worn out, unless damaged by accident or enemy action. The vehicle operator and the organizational level mechanic are responsible for performing preventive maintenance on the batteries of vehicles assigned to the unit.
Each time the vehicle is started and often during its operation, the driver should check the battery-generator indicator located on the dash panel. The battery-generator indicator on tactical vehicles is a meter that shows the level of battery voltage. It has a scale marked off in three colors: red, yellow or amber, and green.
When the ignition switch is first turned on, the indicator hand will usually point to the yellow section, which is the center part of the scale. If the hand points to the red at the left side of the scale, the battery is in a low state of charge. (The hand may point to the green scale on the right if the battery was just recently charged at a high rate.)
If the battery charge is low, find out the cause and make necessary corrections. If a battery is allowed to remain in a low state of charge for very long, the sulfate formed in the plates will harden, and it will be impossible or very difficult to return the battery to a fully charged condition.
When the engine is started, the battery-generator indicator hand will move to the right if the charging system is operating properly. The hand will point to the left half of the green part of the scale when the battery is fully charged.
If the hand moves into the right half of the green scale, the battery is being overcharged. (On some indicators this part of the scale is red instead of green.) The operator should have the charging system checked immediately before the battery or charging system is damaged. Overcharging overheats the battery, causing it to lose water at a fast rate, and can warp the plates causing permanent damage.
If the vehicle is equipped with an ammeter instead of a battery-generator indicator, the operator should check the position of the ammeter hand often during operation. For a fully charged battery, the ammeter should show a high rate of charge immediately after the vehicle is started. After about 15 minutes of operation, the charge rate should drop to about 5 amperes. When the battery is partly discharged before starting, the high-charge rate will continue for a longer period. If the ammeter does not register a charge or if the high-charge rate continues, the charging circuit should be checked immediately.
After operation, check the battery to see that it is clean, securely mounted, and not leaking. Cable terminals should be clean and secure on the battery posts. All vent caps should be present and tight.
The batteries should be thoroughly inspected and serviced once a week by doing the procedures explained below. Either the operator or the mechanic may be called upon to perform these procedures.
Inspect the tops of the batteries very carefully and clean them if needed. They must be kept clean to prevent them from discharging through collected dirt, and so forth. To clean, tighten the vent plugs and wash the batteries with a brush dipped in an alkaline solution, such as a mixture of bicarbonate of soda (baking soda) and water. Foaming will occur due to the reaction between the cleaning solution and battery electrolyte. After the foaming stops, rinse off the batteries with clean water and wipe dry with a clean cloth.
Inspect the battery terminals to see that they are clean and the cable clamps are tight and free of corrosion. If they are corroded, remove the cable clamps and clean the clamps and the battery posts with a solution as described above. Then, reconnect and tighten the cable clamps. Coat the terminals with a light coat of general-purpose grease to fight off corrosion. Dirt will collect on the grease, but it can be removed each time the batteries are cleaned and the terminals recoated with grease. When disconnecting the battery cables, always disconnect the ground cable first to prevent a short circuit. When connecting the cables, connect the ground cable last.
Remove and inspect the vent plugs to see that the vent holes are open. Use a short length of stiff wire to run through the vent holes to make sure they are not plugged, but be careful not to damage the check valves in vent plugs on waterproof batteries.
Inspect the electrolyte level and add water if it is low. Filling instructions are located on the vent plugs or the cell covers. When correct, the electrolyte level will be at least 3/8 inch above the plates. Distilled water should be used to fill batteries if it is available; if it is not available, the second choice is rainwater.
Check the specific gravity of each cell with an optical battery/antifreeze tester.
Inspect the battery hold-downs to make sure that the batteries are held properly in their carriers. If a battery is loose, it may bounce around and damage the container or shake the plates loose inside the cells. On the other hand, if the hold-downs are drawn too tight, the container may crack.
Do not store battery water in metal containers. Minerals in water from streams or wells, or from water stored in metal, can damage and shorten the life of a battery. Water that is used for drinking can be used, but only when distilled water or rainwater is not available. A battery will be damaged less by clean water that has some minerals than by letting the electrolyte level drop below the top of the plates.
OPTICAL BATTERY/ANTIFREEZE TESTER
Since the amount of sulfuric acid in the electrolyte decreases as the battery discharges, the gravity of the battery also decreases as the battery's state of charge decreases. By using a tester, known as an optical battery/antifreeze tester, to measure the gravity of the electrolyte, we can tell the battery's state of charge.
The gravity of the battery is affected by temperature. When heated, the electrolyte expands so it occupies more space. When the temperature drops, the electrolyte contracts and takes up less space. Therefore, warm electrolyte weighs less than the same volume of cold electrolyte, so warm electrolyte has a lower specific gravity than cold electrolyte.
Electrolyte mixed for normal use will test 1.280 at 80°F temperature. (This is the temperature of the electrolyte and not the surrounding air.) At ordinary temperatures, it is not necessary to consider any variations when testing the gravity of a battery. However, any large variation above or below 80° is very important when deciding the true state of battery charge.
The state of the battery charge indicated by gravity readings is shown below.

Other factors to consider when you test the gravity of a battery are the level of the electrolyte and how well the electrolyte is mixed.
The electrolyte should be at the correct level in the cell. Water in the electrolyte evaporates; the acid does not. If the water has evaporated enough so the electrolyte level is low, the mixture will be strong and the gravity reading will be high. On the other hand, if the battery has been overfilled with water, the electrolyte will be weakened and the reading will be low.
When water is added, it will tend to remain at the top of the cell, and you should not test immediately after adding water. If water must be added before a reading, the battery should be charged for one to two hours to mix the electrolyte before the optical battery/antifreeze tester is used.
Gravity readings will not tell the true state of the electrolyte just after a battery has been discharged at a high rate (such as just after the engine has been cranked for a long time). In this case, the acid has been used up next to the plates but the electrolyte near the top of the plates is still strong. The optical battery/antifreeze tester will read a higher state of charge than actually exists. The electrolyte will show a true reading if the battery is allowed to stand unused for several hours or if it is charged for one to two hours.
MEASURING SPECIFIC GRAVITY WITH THE OPTICAL BATTERY/ANTIFREEZE TESTER
This tester is quick, accurate, and reliable. There is no guesswork or arithmetic involved. The tester automatically adjusts for temperature.
The plastic cover and the measuring window must be clean and dry. Wipe clean with a soft cloth. Clean the eyepiece lens. Use clean water to clean dirty areas.
Swing the plastic cover down until it rests against the measuring window.
Make a separate test for each battery cell.
Using the black dipstick, place a few drops of electrolyte onto the exposed portion of the measuring window.
| WARNING Be careful not to splash electrolyte onto you or the equipment. |
Point the tester toward a bright light source. When you look through the eyepiece lens, you will see a rectangle with two calibrated scales - battery charge readings on the left scale, antifreeze readings on the right.
The electrolyte sample will divide the rectangle with an area of light and an area of shadow. You read the scale where they meet.
A full charge is 1.225 specific gravity for tropical electrolyte and 1.280 specific gravity for temperate electrolyte.
If below 1.180 specific gravity for tropical electrolyte and 1.225 specific gravity for temperate electrolyte, replace the battery with a fully charged one if you cannot charge it in the field.
COLD WEATHER
Battery capacity is greatly reduced by low temperatures because the electrolyte thickens and is less active. In addition, the engine is harder to crank so the starter motor requires more current. To perform satisfactorily in cold weather, the battery must be kept in peak condition. So when the temperature drops, you will have to keep a closer watch on the battery.
In cold weather do not let the specific gravity drop below 1.250 if you expect the vehicles to start. When the temperature is colder than -20°F, the vehicles should be stored inside where it is warm, if possible. If they must be parked outside, the batteries should be heated during long periods of standby; otherwise, they will not take a charge or have enough capacity for normal use.
The electrolyte is also subject to freezing; the exact freezing point depends on the specific gravity. In a fully charged battery, the electrolyte will freeze at -90°F. As the specific gravity drops, the freezing point rises. The following table shows the freezing point for various specific gravities.
| Specific gravity | Freezing point, degrees Fahrenheit |
| 1.000 1.100 1.150 1.200 1.250 1.280 | +32 +19 +. 5 -16 -62 -90 |
If the battery electrolyte does freeze, the ice forces active material from the plates and can crack plates and containers or buckle plates and break separators. If you try to charge a frozen battery, the grids expand and shed active material. Let a frozen battery thaw out in a room at normal temperature before charging. The battery may be saved if freezing has not already caused too much damage.
If water is added to a battery, it may freeze if it is not immediately mixed with the electrolyte. For this reason, do not add water in freezing temperatures unless the battery is indoors or the vehicle is operated for at least an hour after the water is added.
TROPICAL CLIMATES
The high temperatures found in the tropics create special maintenance problems that you will have to adjust to if you are assigned in one of those areas.
Rapid evaporation of the water will result due to the heat, so keep a close watch on the electrolyte level. Every effort should be made to keep the battery compartment as cool as possible during and after operation. Do not obstruct ventilation holes, or the heat will damage the batteries.
At high temperatures, the acid in the electrolyte is more active, so using a weaker solution will give good results and cause less damage to the plates and separators.
Electrolyte solution used for tropical climates should have a specific gravity of 1.200 to 1.225. You will have to weaken the solution yourself. Do this by drawing electrolyte from a supply that is already mixed to 1.280 specific gravity and add battery water until the mixture has a specific gravity of 1.200 to 1.225. You will need to add about 1 quart of water to 1 gallon of electrolyte.
If the battery was in use before it was sent to the tropics, change the electrolyte in the following manner. Make sure that the battery is fully charged, so there will be no acid left in the plates. Then, remove the vent plugs and tip the battery upside down to drain all the old electrolyte. Refill the battery with electrolyte that has been weakened to 1.200 to1.225 specific gravity.
| WARNING Avoid getting any of the electrolyte on yourself or your clothes. The acid can cause painful burns and will eat holes in your clothing. |
The following table shows various specific gravities and the state of charge for batteries with weakened electrolyte for use in the tropics.
| Specific gravity of electrolyte used in tropical climates | State of battery charge |
1.200 - 1.225 1.180 1.135 1.090 1.045 | Fully charged 75 percent 50 percent 25 percent Discharged |
When the electrolyte in a battery has been weakened, a tag showing the full charge specific gravity should be attached to the battery. These batteries should also be identified by a white dot about 1 inch in diameter painted on the top of the battery where it can be easily seen.
SLAVING
Normally, the charging system of a vehicle will keep the vehicle's batteries charged. Occasionally, due to excessive cranking, repeated short drives, or a fault in the electrical system, the batteries will become discharged. If the vehicle is in the field where no external method of charging is available, you will probably have to start it by towing or slaving the electrical system of another vehicle.
To slave a vehicle with discharged batteries, you must use heavy-duty jumper cables and connect its dead batteries to the good batteries of a second vehicle. Stay alert when connecting the jumper cables. The hookup must always be positive to positive and negative to negative. If either of the vehicles has an AC charging system, the rectifier will be burned out if you even momentarily touch the cables to the wrong terminals.
Never try to slave one vehicle from another one that has a power source with a smaller ampere-hour capacity rating. In other words, do not slave a 10-ton tractor with four 6TN 100 ampere-hour batteries from a ¼-ton truck with two 2HN 45 ampere-hour batteries. This will only lead to more trouble.
After connecting the jumper cables, run the live vehicle with good batteries at 1,800 revolutions per minute (RPM) for a short while. This allows its charging system to put a slight charge in the discharged batteries which helps a lot when you attempt to crank the dead vehicle. While cranking the dead vehicle, keep the live one running at 1,800 RPM so you can use the power created by its generator.
Remember that batteries will be damaged if left in a discharged state for long. After you get the slaved vehicle started, make sure the vehicle is kept in operation long enough to fully recharge its batteries. If this is not possible, arrange for the batteries to be charged from an external source. If some defect caused the batteries to discharge, get that defect corrected immediately.
Some vehicles are equipped with slave receptacles so a slave (jumper) cable can be easily plugged in. Both vehicles involved must be equipped with these receptacles. A special two-conductor slave cable that fits the receptacles is provided. The proper positive-to-positive and negative-to-negative connection for slaving is made by merely plugging the one-piece slave cable into the slave receptacles of the two vehicles.
CHARGING METHODS
Whenever the gravity of a battery drops below 1.225 (1.135 in tropical climates), it is best to recharge it with a battery charger under controlled conditions. The two principal ways of charging are constant current and constant potential (voltage). The method you use will depend on the equipment and facilities available.
Constant-current charging is usually done only at installations where a regular battery shop is set up. Electrical power is furnished by the 110-volt current supplied by the high lines. Since the 110-volt supply is usually AC, which will not charge batteries, it must be changed to DC. This is usually done by rectifiers.
After the incoming 110-volt power has been changed to DC, it must not be connected directly to a single 12-volt battery or the battery will be ruined. A resistance must be placed in the circuit to limit the current. This can be done by connecting a number of lamps in parallel. A 110-volt, 100-watt lamp consumes about 1 ampere of current, so four bulbs will permit 4 amperes to flow. A variable resistor of the proper value can be used instead of lamps and adjusted to give the desired current.
Several batteries are generally connected in series when charging by the constant-current method, so the power that is consumed by the current-limiting resistance is reduced. When the batteries are connected, their combined voltage should never be higher than the charging voltage. Allow 2.5 volts per cell when you add up the battery voltage. All batteries in the same series should be in about the same condition. Batteries being charged by the constant-current method must be checked often, particularly in the final stages, to avoid overcharging.
Battery chargers supplied for use in the field are the constant-potential type. A charger usually consists of a DC generator powered by a gasoline engine. They are made with 7½- and 15-volt outputs or with a 15- and 28-volt output.
When using the battery charger to charge one 12-volt battery, connect its 15-volt output or load terminals to the battery terminals. Connections must be positive-to-positive and negative-to-negative. If more than one battery is to be charged from the 15-volt output, they must be connected in parallel. If you connect the batteries in series, their voltage will be higher than the charging voltage and the charger could not force current through the batteries.
To charge 12-volt batteries from the 28-volt output of a charger, connect two batteries in series, then connect them to the 28-volt load terminals. To charge more than two batteries, you must connect them in series-parallel. The batteries in each series group should be in about the same condition.
When a battery is first placed on a constant-potential charging system, its voltage is much lower than the charging voltage, so a high current will flow. As the battery is charged its voltage increases, but the charging voltage remains constant. This causes the current to decrease as the battery is charged and to taper off to a very slow rate. Less attention is required near the end, but care must be taken to prevent overheating the battery at first. The constant-potential battery charger is generally equipped with a variable resistor so the operator has some control over the charging rate.
CHARGING PROCEDURES
Batteries should be charged only in the open air or a well-ventilated room because of the gases they expel. Before attempting to charge a battery, give it a thorough cleaning and inspection. Do not waste your time on batteries that are cracked or damaged in any way that will make them unserviceable. Place good batteries on a board or wooden rack. Never stack them on top of each other or on the ground or a concrete floor.
Check and record the specific gravity of each cell of all the batteries to be charged. Add water to bring the electrolyte to the proper level. Arrange and connect the batteries for charging. All batteries connected in one series group should have about the same specific gravity readings. Make sure all the vent plugs are secure and the vents are not plugged, then begin the charge.
Watch closely for overheating or excessive gassing for the first few minutes of charge. If either occurs, reduce the charging rate. For best results, the battery electrolyte should not exceed 110°F temperature. The battery should gas very little when it is first placed on charge, but steady gassing later on when the battery nears full charge is normal.
Check the specific gravity of the battery often while it is being charged. Just how often will depend on the rate of charge. If a charge rate of 2½ amperes for 2HN batteries or 5 amperes for 6TN batteries is being used, check the gravity hourly when the batteries near full charge. You may reduce the time between checks if the charge rate is decreased. Add water to replace any lost during the charge. A battery is fully charged when three successive readings show no further rise in specific gravity.
When the battery is charged, remove it from the charger and clean its top to remove any acid. Inspect the battery once again for any cracks that may have opened due to the charging process. Screw the vent plugs tightly in place. If the battery has handles and the paint on them is worn, apply a coat of acid-resistant black paint.
PLACING BATTERIES IN SERVICE
New batteries that you receive will probably be charged and dry. If they are, you will have to fill them with electrolyte in preparing them for service. The instructions received with new batteries on how to prepare them for service should always be followed. In general, the following instructions apply:
Remove and discard the seals from the ventholes of the vent plugs. Remove the vent plugs and fill each cell with electrolyte to the proper level. The temperature of the battery must be at least 60°F. Let the battery stand for 30 minutes after filling to allow the plates and separators to become soaked, then check the specific gravity of each cell. The electrolyte level must be correct.
The battery is now ready for use unless one or more of the following conditions exist:
The specific gravity of any cell is below 1.250 after the 30-minute stand.
The battery will not be used for 12 hours after filling.
The battery is going into service in temperatures below zero.
If any of the above conditions exists, the battery must be charged. If you have the time and equipment, it is always best to charge the battery regardless of the conditions to ensure longer service life. After charging, the specific gravity should be at or very near 1.280.
When batteries are selected for installation in a vehicle, they should be matched. This applies to both new and charged batteries. If two batteries with one weaker than the other are placed in a vehicle, the vehicle's charging system will overcharge the stronger battery in an attempt to charge the weak one. This causes overheating and loss of water in the stronger battery, shortening its life. In matching batteries, you should pair batteries that have about the same specific gravity and voltage.