3-6. Rafters

Rafters make up the main framework of all roofs. They are inclined members spaced from 16 to 48 inches apart. They vary in size, depending on length and spacing. The tops of inclined rafters are fastened to the ridge or another rafter, depending on the type of roof. Rafters rest on the top wall plate. Rafters are nailed to the plate, not framed into it. Some are cut to fit the plate, while in hasty construction they are merely laid on top of the plate and nailed in place. They may extend a short distance beyond the wall to form the eaves and protect the sides of the building. Sometimes, metal anchor are used to connect joints and rafters to the top plate (see Figure 3-7 ). Metal anchors permit rapid installation of joist and rafters, eliminating the need for nailing them. Metal anchors are fastened with 1 1/4 inch nails.

Figure 3-7.  Metal anchors
Figure 3-7. Metal anchors

a. Types. Examples of most types of rafters are shown in Figure 3-8 . The four types of rafters used are common, hip, valley, and jack.

Figure 3-8.  Roof framing terms
Figure 3-8. Roof framing terms

(1) Common rafters. These are framing members that extend at right angles from the plate line to the roof ridge. They are called common rafters because they are common to all types of roofs and are used as the basis for laying out other types of rafters.

(2) Hip rafters. These are roof members that extend diagonally from the corner of the plate to the ridge.

(3) Valley rafters. These rafters extend from the plate to the ridge along the lines where two roofs intersect.

(4) Jack rafters. These are a common rafter. The three kinds of jack rafter are the--

b. Rafter Layout. Rafters must be laid out and cut with the slope, length, and overhang exactly right so that they will fit when placed in the roof.

(1) Scale or Measurement Method. The carpenter should first determine the length of the rafter and the length of the lumber from which the rafter may be cut. If he is working from a roof plan, he learns the rafter lengths and the width of the building from the plan. If no plans are available, the width of the building must be measured.

To determine the rafter length, first find one-half of the distance between the outside plates. (The amount of rise per foot has yet to be considered.) If the building is 20 feet wide, half the span will be 10 feet.

As an example, use a rise per foot of 8 inches. To determine the overall length of a rafter, measure on the steel carpenter's square the distance between 8 on the tongue and 12 on the blade (8 is the rise, and 12 is the unit run). This distance is 14 5/12 inches. This represents the line length of a rafter with a total run of 1 foot and a rise of 8 inches (see Figure 3-9 ).

Figure 3-9.  Steel carpenter's square
Figure 3-9. Steel carpenter's square

Since the run of the rafter is 10 feet, multiply 10 by the line length for 1 foot (10 x 14 5/12 = 144 2/12). The answer is 144 2/12 inches or 12 feet 1/6 inch. The amount of overhang, normally 1 foot, must be added if an overhang is to be used. This makes the total length of the rafter 13 feet 1/6 inch. Use a 14-foot timber.

(2) Pattern Rafter Method. After the length has been determined, the timber is laid on sawhorses (saw benches) with the crown or bow (if it has any) as the top side of the rafter. If possible, select a straight piece for the pattern rafter. If a straight piece is not available, have the crown toward the person laying out the rafter. Figure 3-10 illustrates the five steps of the pattern rafter method.

Figure 3-10.  Rafter method
Figure 3-10. Rafter method

(3) Step-Off Method. The rafter length of any building may be determined by "stepping it off" by successive steps with the square, as follows:

Figure 3-11.  Step-off Method
Figure 3-11. Step-off Method

NOTE: When laying off rafters by any method, be sure to recheck the work carefully. When two rafters have been cut, it is best to put them in place to see if they fit. Minor adjustments may be made at this time without serious damage or waste of material.

(4) Table Method 1. To use the framing square to lay out rafters, the width of the building must first be known. Suppose the building is 20 feet 8 inches wide, and the rise of the rafters is to be 13 inches per foot of run. The total run of the rafters will be 10 feet 4 inches.

Figure 3-12.  Table Method 1
Figure 3-12. Table Method 1

(5) Table Method 2. The rafter table is on the back of the blade of some squares. Figure 3-13 shows the run, rise, and pitch of the rafters of the seven most common roof pitches. The figures are based on the length of the horizontal measurement of the building from the center to the outside (run). The rafter table on the outside edge, on the back of the square, gives both the body and the tongue in twelfths. The inch marks on the square may represent inches or feet, and the twelfth marks may represent twelfths of an inch or twelfths of a foot. The rafter table is used in connection with the marks and figures on the outside edge of the square. You will notice that at the left end of the table there are figures representing the run, rise, and the pitch.

Figure 3-13.  Table Method 2
Figure 3-13. Table Method 2

Figure 3-14.  Pitch on the rafter table
Figure 3-14. Pitch on the rafter table

c. Assembly. Rafters are usually made into trusses. Two rafters are connected at the top, using a collar tie well nailed into both rafters. Before any ties or chords are nailed, the rafters should be spread at the lower end to equal the width of the building. This is done by using a template or by measuring the distance between the seat cuts with a tape (see Figure 3-15 ).

Figure 3-15.  Assembling a truss
Figure 3-15. Assembling a truss

(1) Chord. A 1 by 6 or 2 by 4 chord is nailed across the rafters at the seat cut to tie them together. This chord forms a truss with the two rafters. A hanger or vertical member of 1 by 6 is nailed to the rafter joint and extends to the chord at midpoint, tying the rafter to the chord.

(2) Collar Beam. A tie or collar beam is a piece of stock (usually 1 by 4, 1 by 6, 1 by 8, or 2 by 4) fastened in a horizontal position to a pair of rafters between the plate and the ridge of the roof This type of beam tends to keep the building from spreading. Most codes and specifications require them to be 5 feet apart or every third rafter, which ever is less. Collar ties are nailed to common rafters with four 8d nails to each end of a 1-inch tie. If 2-inch material is used for the tie, they are nailed with three 16d nails at each end. This type of bracing is used on small roofs where no ceiling joists are used and the building is not wide enough to require a truss. The lower the collar beam or chord, the better it works.

(3) Support. In small roofs that cover only narrow buildings and in which the rafters are short, there is no need for interior support or bracing. In long spans, the roof would sag in the middle if it were not strengthened in some way. To support long rafters, braces or other types of supports must be installed.

(4) Rafter Support. In wide buildings, where the joists or chords must be spliced and there is no support underneath, the rafter and joists support one another (see Figure 3-16 ).

Figure 3-16.  Rafter support detail
Figure 3-16. Rafter support detail

d. Knee Brace. If no additional bracing is needed, the truss is set in place on the plates. If additional bracing is needed, a knee brace is nailed to the chord. The knee brace forms a 45° angle with the wall stud. For easier erection, the knee brace may be omitted until the rater truss is set in place (see Figure 3-16 ).