Part of your job as a certified mechanic is to maintain and repair air-conditioning systems. You will need to understand how air-conditioning systems function before you can become a competent troubleshooter. This manual gives you the foundation to recognize problems and repair them. Your knowledge in this area is essential to the successful completion of a job or unit mission. This manual introduces you to the fundamental operating principles, parts, and maintenance of air-conditioning systems, and operating problems that you may experience. When you have completed this manual, you will be able to:
1.0.0 PRINCIPLES of REFRIGERATIONRefrigeration is the process of producing low temperatures. It is usually associated with refrigerators or freezers rather than with vehicles. An understanding of heat transfer, basic refrigeration, pressure temperature relationship, and the qualities of refrigerants is essential for a working knowledge of the air-conditioning system. 1.1.0 Heat TransferIt may seem odd to cover heat transfer in connection with air conditioning. Keep in mind, however, that heat, like light, is a form of energy. As you remove light, a room grows darker. Likewise, when you remove heat, an area becomes colder. The process of transferring heat is the basis for air conditioning. Generally, when two objects of different temperatures are close to each other, heat energy will leave the warmer object and travel to the cooler. This is quite clearly illustrated in North America each fall and winter. As the rays of the sun become less direct and consequently give off less heat, we experience a drop in temperature. Cooler weather (refrigeration) results from this removal of heat. Refrigeration applies a physical principle that is known to most of us through our everyday experiences. We have experienced the application of rubbing alcohol and its cooling effect. This example illustrates that an evaporating liquid absorbs heat. The evaporating moisture in the air on a hot day soaks up heat like a sponge. This removal of heat is exactly the same process used in automotive air conditioning. Heat is removed from the vehicle by an evaporating refrigerant and transferred into the atmosphere. 1.2.0 Pressure Temperature RelationshipDifferent liquids have different boiling evaporating points; however, the boiling point of any liquid increases when pressure is increased. When pressure is decreased, the boiling point is then decreased. This process of removing the pressure and allowing the coolant to boil is a vital part of any refrigeration system. 1.3.0 Refrigerant (134A)With the exception of changes in state, gases used in refrigeration are recycled much like engine coolant. Different pressures and temperatures cause the gas to change state from liquid to gas and back to a liquid again. The boiling point of the refrigerant changes with system pressure. High pressure raises the boiling point and low pressure reduces it. These gases also provide good heat transfer qualities and do not deteriorate system components. A few years ago, vehicles were cooled with refrigerant-12 (R-12). It had a boiling point of 220�F and vaporized at room temperature. Because R-12 has been found to be hazardous to the environment, it has been fased out. The replacement refrigerant is R-134a. 1.4.0 Handling RefrigerantR- 4a is a relatively safe refrigerant; however, you must observe certain precautions when using and handling it:
Figure 1 - Warming the refrigerant with warm water.
Some systems may still have R-12 in them. Here are some differences in the systems to help you identify them and the precautions involved:
1.5.0 Refrigeration CycleThe refrigeration cycle is a continuous closed-loop system. The refrigerant is pumped constantly through the components in the system. By changing the refrigerant pressure and by removing and adding heat, the refrigeration cycle is completed. The refrigeration cycle operates as follows:
2.0.0 COMPONENTS of the AIR CONDITIONING SYSTEMEach air-conditioning system (Figure 2) must have a receiver/drier, an expansion valve or metering device, an evaporator, a compressor, and a condenser. Without these components, an air-conditioning system will not function. Additionally, the system must have some means of control. The following information briefly covers each air- conditioning component and the controls involved.
Figure 2 - Air-conditioning system. 2.1.0 The Receiver/DrierThe receiver (Figure 3), otherwise known as a filter-drier or accumulator-drier, is a cylindrical-shaped metal tank that has two purposes; separate liquid from gas and to remove moisture and filter out dirt. The tank is hollow with an inlet to the top of the hollow cylinder. The outlet port has a tube attached to it that extends to the bottom of the receiver. This tube assures that only liquid refrigerant will exit the receiver because any gas entering will tend to float above the liquid.
Figure 3 - Receiver and components. Some other components of the receiver/drier are:
Figure 4 - Possible sight glass conditions. 2.2.0 The ExpansionThe refrigerant expansion system is designed to regulate the amount of refrigerant entering the evaporator and to reduce its pressure. 2.2.1 Expansion ValveOne type of expansion system used on modem vehicles is the expansion valve (Figure 5, View A). The valve action is controlled by the valve spring, suction manifold, and pressure exerted on the diaphragm from the thermal bulb. Operation of the valve is as follows:
As the refrigerant flows, it cools the evaporator and therefore reduces pressure in the thermal bulb. This allows the valve to close and stop refrigerant from flowing into the evaporator. By carefully metering the amount of refrigerant with the expansion valve, the evaporator cooling efficiency is increased greatly. 2.2.2 Expansion TubeThe expansion tube (Figure 5, View B) provides the same functions as the expansion valve. A calibrated orifice is built into the expansion tube. The tube retards the refrigerant flow through the orifice to provide the metered amount of refrigerant to the evaporator. The tube also has a fine screen built in for additional filtration.
Figure 5 - Expansion valve and tube. 2.3.0 The EvaporatorThe evaporator is designed to absorb heat from the airstream directed into the driver's compartment. It is a continuous tube looped back and forth through many cooling fins firmly attached to the tube. The evaporator dehumidifies the air by passing an airstream over the cooling fins. As this happens, the moisture condenses on the fins and drips down to collect and exit under the vehicle. Also, dust and dirt are collected on the moist fins and are drained with the moisture. The temperature of the evaporator must be kept above 32�F. Should the temperature fall below 32�F, moisture condensing on the evaporator will freeze and prevent air from passing through the fins. A typical evaporator is shown in Figure 6. There are basically three methods of regulating evaporator temperature; each is examined below.
Figure 6 - Typical evaporator. 2.3.1 Thermostatic SwitchThis system uses an electrically operated thermostatic switch (Figure 7) to engage and disengage the compressor. The switch is operated by a sensing bulb placed in the airstream after the evaporator. As the evaporator temperature falls, the thermostatic switch opens to disengage the magnetic clutch in the compressor. When the coil temperature reaches the proper level, the switch again closes to engage the clutch and drive the compressor.
Figure 7 - Thermostatic switch. 2.3.2 Hot Gas Bypass ValveThe hot gas bypass valve (Figure 8) was used on some older models to control evaporator icing. The valve is mounted on the outlet side of the evaporator. The high-pressure gas from the compressor joins with the low- pressure gas exiting the evaporator. These two gases mix, causing a pressure increase. Also, the boiling point increases, which results in a loss of cooling efficiency. This, in turn, causes the evaporator temperature to increase, thus eliminating freeze-up. The compressor is designed to run constantly (when it is activated) in the hot gas bypass valve system.
Figure 8 - Hot gas bypass valve operation. 2.3.3 Suction Throttling Valve
Figure 9 - Suction throttling valve. The suction throttling valve (Figure 9) is now used in place of the hot gas bypass valve system. It is placed in line with the outlet of the evaporator. This system is designed to limit the amount of low-pressure vapor entering the compressor. The suction throttling valve operates as follows:
As pressure again drops on the inlet side of the valve, atmospheric pressure and valve spring pressure close the valve again. A vacuum power unit is mounted to the top of the valve to help reduce valve spring pressure and prevent icing at high elevations. 2.3.4 Pilot-Operated Absolute Suction Throttling ValveThe pilot-operated absolute (POA) suction throttling valve (Figure 10) maintains the proper minimum evaporator pressure regardless of compressor speed, evaporator temperature, and changes in altitude. The POA suction throttling valve is operated by a bellows containing an almost perfect vacuum. The expanding and contracting action of the bellows operates a needle valve, regulating its surrounding pressure. As inlet and outlet pressure are equalized, spring pressure closes the valve. The pressure differential across the valve then forces the piston toward the lower pressure, therefore opening the valve to allow refrigerant to flow.
Figure 10 - Pilot-operated absolute suction throttling valve. 2.4.0 The CompressorThe compressor increases the pressure of vaporized refrigerant exiting the evaporator. When the system is activated, a coil produces a magnetic field that engages the drive pulley to operate the compressor (Figure 11). Some compressors are protected from overheating by a superheat switch located inside the compressor. Should the compressor develop an excess amount of heat due to a loss of refrigerant or oil, the superheat switch disengages the compressor by completing a circuit and opening a thermal fuse. Sometimes a compressor discharge pressure switch is used to protect against a low refrigerant condition. This switch disengages the compressor drive to protect the system when discharge pressure drops below approximately 35 psi (241 kPa). Often a muffler is used on the outlet side of the compressor. The muffler helps reduce compressor pumping noise and line vibrations.
Figure 11 - The compressor and its components. 2.5.0 The CondenserThe condenser (Figure 12) is designed to remove heat from the compressed refrigerant, returning it to a liquid state. Generally, condensers are made from a continuous tube looped back and forth through rigidly mounted cooling fins. They are made of aluminum and can encounter pressures of approximately 150 to 300 psig and temperatures ranging from 120�F to 200�F (48�C to 93�C). Usually, the condenser is mounted in front of the radiator and is subjected to a steady stream of cooling air.
Figure 12 - The condenser. Refrigeration oil provides lubrication for the compressor. Each system has a certain amount of refrigeration oil (usually approximately 6 to 10 ounces (177 to 296 Ml)) added to the system initially. If the system stays sealed, the oil will not break down or need to be changed. Refrigeration oil is highly refined, must be free of moisture, and is designed for use in automotive air-conditioning systems.
3.0.0 MALFUNCTIONS of COMPONENTS in the AIR- CONDITIONING SYSTEMProblems in automotive air-conditioning systems are not uncommon. An ordinary industrial system does not have to contend with the vibration that a mobile unit does. What follows is a list of common problems and possible causes associated with each air-conditioning component. This is by no means a complete list, so you should have the manufacturer's vehicle repair manual handy. 3.1.0 The CompressorA thumping noise in the compressor or a cool and sweating compressor suction line accompanied by no cooling is usually caused by too much refrigerant in the system. If there is no moisture in the system, the excess refrigerant should be removed and stored for proper disposal. If moisture is present, you must discharge, evacuate, and recharge the system. 3.2.0 The CondenserThe condenser unit could have clogged fins that limit the cooling ability of the unit. This could be caused by bugs, leaves, or other debris caught in the tins. This can be corrected by using air pressure to blow out the coils, Check for any icy or frosty spots on the condenser. An abnormally cold spot usually indicates partial restriction inside the condenser coils at that point. Restrictions are normally caused by foreign matter. Correct this condition by discharging and purging the system. 3.3.0 The EvaporatorThe evaporator is normally maintenance free for the life of a vehicle. If the evaporator does develop a leak, it will be necessary to remove the assembly for repair. An evaporator is repaired in the same manner as a radiator. If the evaporator does not get the right amount of refrigerant, the expansion valve is most likely at fault. 3.4.0 The Expansion ValveThe most common malfunction in the expansion valve is icing caused by moisture in the air-conditioning system. The system must be discharged and evacuated to remove all moisture. On occasion, the expansion valve may stick open or closed; in this case, you must replace the valve. 3.5.0 The Receiver/DrierThe receiver/drier may become saturated with moisture, or the filter may become restricted. If the receiver/drier is saturated or restricted, replace it. For any of these repairs, comply with the appropriate maintenance manual.
4.0.0 INSPECTING the AIR CONDITIONING SYSTEM for LEAKSApproximately 80 percent of all air-conditioning service work consists of your inspecting for and repairing leaks. Many leaks will be located at points of connection and are caused by vehicle vibration. They may only require the retightening of a flare connection or a clamp. Occasionally, a hose will rub on a structural part to create a leak, or a hose may deteriorate and require replacement. The compressor shaft seal may also require occasional replacement. Anytime the system requires more than one-half pound of refrigerant after operating during one season, a serious leak is indicated that you must locate and repair. The following information covers a few of the various means of detecting leaks.
4.1.0 Internally Charged DetectorThis detector is a specially colored leak detector available in a pressurized can and mixed with R-134a. It can be introduced into the air-conditioning system with regular charging equipment. When a leak occurs in the system, a bright red-orange spot appears at the point of leakage and remains until it is wiped off. The internal leak detector remains in the system and will spot future leaks in the same manner. A sticker is usually placed under the vehicle hood to indicate that the system is charged with a leak detector. 4.2.0 Bubble DetectorThe bubble detector is a solution applied externally at suspected leak points. Leaking refrigerant will cause the detector to form bubbles and foam. 4.3.0 Electronic DetectorThis instrument indicates leaks electronically by flashing a light or sounding an alarm. There are several different types of electronic detectors. Directions for using the instruments are furnished by the manufacturer. This type of electronic leak detector is the one most widely used today (Figure 13).
Figure 13 - Electronic leak detector. 5.0.0 PURGING THE AIR-CONDITIONING SYSTEMAnytime an air-conditioning system is discharged and opened before it is returned to service, it must be evacuated and recharged. To perform this operation, you need certain tools, such as a vacuum pump (Figure 14, View A), a gauge manifold set (Figure 14, View B), and a leak detector. Using the vacuum pump, draw the system down to at least 29 inches of mercury at sea level and hold it there for at least 30 to 45 minutes. This will remove all moisture from the system.
Figure 14 - Vacuum pump and gauge manifold set. As the system is being pumped down, the vacuum should drop to the required inches of mercury. If it does not drop, this is an indication of a leak; in which case you must recharge the system to detect the leak. After you detect the leak, repair the damage and re-evacuate the system. Once the system is totally evacuated, again close both valves on the gauge manifold set, disconnect the vacuum pump, and connect the refrigerant source.
In the past, when a system was discharged before disassembly, the standard practice was to vent the refrigerant into the atmosphere. For environmental and legal reasons, this is no longer permissible. The proper procedure is to use a refrigerant recovery/recycling device (Figure 15) and reuse the refrigerant. You are to turn in excess used refrigerant to the Defense Recycling and Management Office (DRMO) for proper disposal.
Figure 15 - Refrigerant recovery/recycling device.
6.0.0 ADDING REFRIGERANT to the AIR-CONDITIONING SYSTEM
Figure 16 - Adding refrigerant to the air conditioning system. Now that the system is pumped down, leave the gauge manifold set attached and attach your refrigerant source, as shown in Figure 16. You are to take the following actions:
7.0.0 FUNCTIONAL TESTING of the AIR-CONDITIONING SYSTEMFunctional testing is required to establish the condition of all components in the system. The engine must be running and the air-conditioning system operating when performing this test. After the initial charge of refrigerant is installed into the system, watch the manifold gauge set. Correct pressure should be 15 to 30 psi for the low side and 175 to 195 psi for the high side. Evaluate the reading you receive against the standard chart in Table 1. If the vehicle you are working on is equipped with a sight glass (Figure 4), the bubbles should disappear at the correct pressures. Close the low side gauge manifold set hand valve. Check the temperature of the air exiting the cooling duct. It should be close to 40�F with the blower running on low speed. Stop the engine and disconnect the gauge manifold set. Table 1 - Temperature Pressure Relationship.
SummaryIn this manual, you learned how to inspect, fill, and troubleshoot air-conditioning systems found in late model vehicles. Keeping the operators comfortable is an important aspect of being a certified mechanic. It is also important to know that you cannot let the refrigerant loose into the environment, and you now know some of the other hazards associated with refrigerant. Types of refrigerant and the oils the systems use can be ever changing with the environmental hazards associated with them, so stay up to date on what is required of you and your air-conditioning system. When you have mastered the knowledge of these systems, you will become a better mechanic.
Review Questions1. If two objects have different temperatures and are close to one another, heat energy travels in what direction, if any?
2. A sizeable amount of refrigerant-134 in the atmosphere may cause what result?
3. When warming a container of refrigerant-12, you should not exceed what temperature?
4. What is the purpose of the desiccant located inside the receiver?
5. The relief valve opens between approximately what pressure ranges?
6. When you observe bubbles in the site glass of an air-conditioning system, what does it indicate?
7. The expansion tube retards refrigerant flow and performs what other function?
8. The evaporator should be kept above what temperature in degrees?
9. Where is the thermostatic switch-sensing bulb located in an air-conditioning system?
10. In an air-conditioning system, what does the suction throttling valve limit?
11. In an air-conditioning system that uses a pilot-operated absolute suction throttling valve, by what means does the valve close as the inlet and outlet pressures equalize?
12. A compressor discharge pressure switch is used to protect against what air- conditioning system problem?
13. The air-conditioning system compressor muffler reduces noise along with what other problem?
14. In an air-conditioning system, where is the condenser usually mounted?
15. Approximately how much refrigeration oil is contained within each system?
16. In an air-conditioning system, when the compressor produces a thumping noise and no cooling, it is an indication of what condition?
17. An abnormally cold spot on a condenser could indicate what condition?
18. What action must you take if the receiver/drier is saturated?
19. Which of the following is the most widely used refrigerant leak detector in use today?
20. The air-conditioning system that is being evacuated must be drawn down to 29 inches and held for how many minutes?
21. What is normally done with excess used refrigerant?
22. What is another name for the low side of the compressor?
23. During the functional testing of an air-conditioning system, what should be the temperature of the air exiting the cooling duct?
Copyright � David L.
Heiserman |