LESSON 5
DESIGN CLOSED CULVERTS
Critical Tasks: 01-1990-20-1002
LESSON DESCRIPTION:
This lesson covers the aspects of designing a culvert (closed channel) for a given situation. In summary, this means selecting the right size, shape, and construction material, plus planning the placement. Design is based on environmental considerations such as slope, flow, and length of culvert needed, in addition to economic considerations.
TERMINAL LEARNING OBJECTIVE:
| ACTION: | Identify characteristics of closed culverts, determine factors for placement of closed culverts, and design closed culverts. |
| CONDITION: | You are given this subcourse, a No 2 pencil, paper, and an ACCP examination response sheet. |
| STANDARD: | Demonstrate competency of the task skills and knowledge by responding correctly to 70 percent of the examination questions. |
| REFERENCES: | The material contained in this lesson was derived from the following publications: None |
The purpose of this instructional material is to discuss, explain, and illustrate the factors that enter into the design, placement, and construction of culverts.
Before proceeding, it is necessary to define the terms found in general use in culvert practice. Look at figure 5-1 for the terms used.

Figure 5-1. Cross-section of culvert in place
PART A - THE THEORY OF CLOSED CHANNEL FLOW
The flow or discharge capacity (Q) of a culvert is the amount of water which the culvert will carry in a unit of time, expressed in cfs. For a particular culvert, Q is controlled by one or more of the following factors:
Remember that the discharge capacity of a culvert will be increased, particularly in short culverts on steep slopes, by a smooth-transition type of inlet.
The Theory of Closed Channel Flow, like the principles of open channel flow, holds with the conservation of mass; that is, it assumes that the flow is continuous, that there is no ponding, and that the flow occurs at crown elevation (free flowing). Therefore, neither the inlet nor outlet can be submerged. To design a pipe with a given Q the engineer must take into consideration four factors:
PART B - FOUR TYPES OF CULVERTS
Culverts are classified as either permanent or expedient (improvised).
| Permanent Structures | Expedient Structures | |
| Concrete box Concrete pipe Corrugated metal pipe (CMP) Pipe arch Clay or other pipes |
Lumber Log Oil drum Sand bag with pierced-steel Plank or logs |
In this lesson we are concerned with four types of pipe: CMP, concrete pipes, concrete box culverts, and expedient.
CMP is available in the diameters and gauge listed. It comes in nestable half-sections that, when assembled, give two-foot effective lengths. The following construction techniques should be used in the installation of CMP:
Consider using concrete pipe when it is available. Concrete pipe has three advantages over CMP. First, it is stronger, and therefore requires less cover than CMP to support the same load. Second, the interior surface is smoother (Manning's "n" = 0.013). This means that a concrete pipe, the same diameter and set on the same slope as one of corrugated metal, will carry a higher Q. Third, concrete pipes are easily made and are more readily available in remote areas. There are two factors to keep in mind when constructing concrete pipe culverts.
Concrete box culverts have good hydraulic capacity and therefore can be considered for use where it is necessary to utilize the full area of the waterway. Additionally, they can be designed to withstand external loads with little or no cover. They are especially adaptable to culvert sites in rock cuts where bedding may be a problem restricting the use of other types of culverts. One possible disadvantage is that the design of concrete boxes requires a knowledge of reinforced concrete design. The construction requires close supervision because the concrete form work, the placement of the reinforcing steel, and the concrete mix itself is critical.
Culverts built of lumber are usable in the TO. When used, an end area equal to the end area of CMP on the same slope can be used for hydraulic capacity. When constructing a lumber culvert remember these three factors:

Figure 5-3. Lumber culvert cover

Figure 5-4. Spiking and fastening a lumber culvert
Logs can be used for expedient culvert and if properly constructed should function until replaced by a permanent structure. For capacity, the end area should be equivalent to CMP for the same slope. In constructing log culverts remember these things:
Expedient culverts can be constructed of sand bags bridged with either pierced steel planks or logs. The deck should be covered with burlap or brush to seal openings and prevent loss of soil.
Oil, gasoline, or asphalt drums can be used for expedient culverts. The capacity of these culverts can be taken as equivalent to the same diameter CMP set on a similar slope.
Remember to provide cover of a minimum of three feet over culverts of this type. When drums are used, care should be taken to remove the top and the bottom. Be cautious when cutting out the ends with a cutting torch if the drum contained flammable material. The joints between the drums should be fully welded. If this cannot be done, some provision should be made to seal the joints to prevent the culvert water from saturating the fill.
WARNING Using a torch to open drums is not recommended. |
PART C - CULVERT PLACEMENT IN DITCH DESIGN
The relationship of the culvert to the bed of the stream is of major importance. Improper location can cause the stream to seek a path other than through the culvert, and the project may be destroyed. Certain techniques can be used to lessen the probability of this occurring, such as the following:
Place the culvert directly in the stream bed, (see figure 5-5(a)) even though it may be diagonal to the structure. If no change is made in the hydraulics of the channel, the stream will not change its direction.

Figure 5-5A. Culvert placement

Figure 5-5B. Culvert placement

Figure 5-5C. Culvert placement

Figure 5-5D. Culvert placement
Normally, culverts are placed on the same slope as the material and artificial drainage channel. However, for culverts to be self-cleaning the velocity of flow should be at least three fps. To achieve this velocity, culverts should not, if practicable, be set on a slope less than 0.4 percent. To prevent excessive velocity, which could cause outlet erosion, the culvert grade should not exceed the critical slope for the particular pipe size being used. Critical slope is the minimum slope of the hydraulic gradient that will permit the maximum Q (flow or discharge).
Culverts should be located wherever natural drainage channels are large enough to require cross drainage. On side-hill roads or where in-place roads intercept surface water, either in cut or in fill, the water is drained to the low side of the road, and, if possible, away from the road by ditch-relief culverts. On 8-percent grades, ditch-relief culverts should be placed about 300 feet apart; on 5-percent grades, 500 feet apart. The distance between the pipes in multiple-pipe culverts should be at least one-half the diameter of the pipe. See figure 5-6.

Figure 5-6. Maximum culvert specifications for CMP for vehicular traffic on roadways
only
PART D - COVER, BEDDING, AND FILL FOR CMP
The function of the cover (figures 5-1 and figure 5-6) over culverts is to prevent crushing of the pipe by distributing the live loads over a larger area. The depth of the cover required is a function of the live loads and the culvert diameter and material. CMP will be the only type of culvert discussed in this lesson.
Cover requirements for CMP can be divided into two categories. The minimum amount of cover required to protect the culvert against crushing by vehicular or aircraft loads is--

Table 5-1. Characteristics of US aircraft
There is a maximum depth of cover for a particular pipe diameter and gauge. This requirement is necessary, since the weight of a large soil mass could crush or distort the culvert.
Table 5-2 gives the cover requirements for culvert under airfields. This table is composed of a series of charts, based on aircraft load and gear configurations. Each of these charts is headed by a weight and gear type. These charts are good for 5,000 pounds more than listed (such as the chart headed "60,000-lb Single Wheel" is good for single wheel loadings up to, and including 65,000 pounds).
Table 5-2. Minimum cover requirements, in feet, for airfields (CMP)
Each chart is subdivided into columns headed by culvert diameters (in inches) and rows based on the gauge of the metal. Linear interpolation can be used for the incremental diameters not listed. The body of the chart gives the cover required, in feet, for the diameter and gauge of pipe concerned.
To use this table, find the chart that applies to the particular aircraft wheel/gear load and landing gear type. When the proper chart is located, read down the left column of the table to determine the appropriate row for the gauge concerned. When the proper row has been found, read horizontally to the right and under the column headed with the pipe diameter in question, the minimum cover, in feet, will be found. Examples are shown below:
60,000-lb Single Wheel - 8-gauge pipe
| Pipe Diameter | 36" | 42"* | 48" | 54" | 60" |
| Cover Required | 2.5 | 2.75 | 3.0 | 3.25 | 3.5 |
27,500-lb Single Wheel- 12-gauge pipe (use 25,000-lb Single Wheel)
| Pipe Diameter | 24" | 30"* | 36" | 42" | 48" |
| Cover Required | 1.5 | 1.75 | 2.0 | 3.5 | 3.0 |
*Linear interpolation between sizes listed.
Culverts are constructed on a firm, well-compacted soil foundation, except box or arch culverts which may be placed on a rock foundation when suitable rock is encountered. The foundation is always shaped to fit (or to bed) about one-fourth of the outside circumference of the pipe or to a minimum depth of one-tenth the diameter. In addition, foundations for pipe culverts are generally cambered or convexed upward.
The bed is laid so that the invert of the pipe is at grade. The culvert site should be checked to determine the composition of the soil. If the bedding is composed of a good granular material, only enough will be required to form a properly compacted and shaped bed. A poor bottom, composed of organic material, muck, silt, or material large enough to puncture the pipe, will require removal and replacement. The depth of the material that must be removed will depend upon the actual site conditions.
Care must be taken in the compaction of the soil in the backfill operation of culvert placement, because the fill must support the loads to prevent the culvert from crushing. Compaction is accomplished in six-inch layers if done by hand mechanical tampers and not over four inches if by hand tampers. Backfilling and compaction are done by hand to a minimum of one foot above the top of the culvert. During this operation the layers should be kept at the same elevation on both sides of the pipe. When compacted fill is 12 inches over the top of the pipe, fill and compaction can be made using mechanized equipment. Special attention must be given to the backfill and compaction beneath the diameter of the pipe. This is the most difficult area to fill and compact, and the most often neglected. Before compacting the backfill, CMP of 48 inches and over should be internally strutted, as shown in figure 5-7 to elongate the vertical dimension. The struts are removed after the compaction operation has been completed.

Figure 5-7. Backfill compaction of CMP of 48 inches and over
Headwalls and wingwalls are constructed to prevent and control erosion, guide water into the culvert, reduce seepage, and hold the end of the culvert in place. These structures are costly in both time and materials. When possible, to avoid expense, extend the outlet and use riprap and/or rubble at the toe of the slope. See figure 5-8.

Figure 5-8. Placement of riprap and rubble
The inlet end of the pipe should be extended so that a minimum sized headwall is required. On steep grades, a headwall is necessary at the outlet side to hold the culvert sections in place. Headwalls should not protrude above the shoulder grade and should be located at least two feet outside the shoulder to avoid being traffic hazards.
Wingwalls are required to channelize water and prevent washing out of headwalls. Their height should prevent embankment material from spilling into the waterway. Figure 5-9 illustrates three types of headwalls.

Figure 5-9. Three types of headwalls
PART E - DESIGN OF PIPE CULVERTS WITH UNSUBMERGED INLETS
The factors to be applied to the design of these culverts are determined as follows:
STEP 1. Determine the rate of runoff. Use the area the culvert must drain. This will be the required capacity, Qp, of the culvert.
STEP 2. Determine culvert use. Will it be used for a road or an airfield?
STEP 3. Calculate the critical dimensions from the cross sections. See figure 5-10. Determine the length in place (LIP) and the fill critical (Fc).

Figure 5-10. Calculating cover
STEP 4. Determine the largest pipe for the fill. Begin from the cross section at the outside edge of the shoulder on the inlet side of the culvert. Consider only pipes that are available and for which cover is adequate.
For roadway loadings, the maximum culvert diameter is equal to two-thirds of the minimum fill (FT from figure 5-10). The cover required for culvert protection is equal to one-half the diameter of the culvert or 12 inches (whichever is greater).
For runways and taxiways sustaining aircraft wheel loads, refer to table 5-1 for the loads, and table 5-2 for the minimum cover required.
STEP 5. Determine the culvert capacity, Qp, and outlet velocity using table 5-3.
Table 5-3. Capacity (Qp) and outlet velocity (V) of CM
("n" = .024) (CMP)
CMP ("n" = 0.024) (CMP)
STEP 6. Determine the number of culvert pipes required. Divide the area runoff, Q by the pipe capacity, Qp. Round up to the next whole number. Use the smallest diameter pipe that can be used with the least number of pipes side by side.
STEP 7. Determine the order length (OL). The OL is calculated by multiplying the number of pipes (NP) times the LIP times a waste and grade correction factor of 1.15. (See Step 3 for the LIP and Step 6 for the NP).
STEP 8. Determine the maximum permissible discharge velocity, Vmax. Use table 4-1 to calculate Vmax for the channel lining into which the culvert outlet will discharge. Determine the correct pipe to be used. Apply the following criteria in your calculations:
PART F - EXAMPLE (UNSUBMERGED INLET)
Determine the most economical pipe size and the quantity of pipe required for a culvert located under a runway, with the general data cross section given below. The maximum using aircraft weight class for this example will be an SR-71C.
No headwall will be constructed downstream. The following are known conditions:
Referring to figure 5-11 note that the following information is required before design can be accomplished:

Figure 5-11. Calculating cover (sample problem)
Solution:
STEP 1. Determine the runoff rate. Given for this example Q = 32 cfs.
STEP 2. Determine airfield culvert use.
STEP 3. Calculate the critical dimensions. Computations should be made in the following sequence (see figure 5-11).
F1= EL1 - EL2
F1 = 607.00 - 600.80 = 6.20 ft
S1= F1 x X
S1 = 6.20 x 10 = 62 ft
F2 = EL3 - EL4
F2 = 607.00 - 599.62 = 7.38 ft
S2 = F2 x Y
S2 = 7.38 x 10 = 73.8 ft
| S | = | EL2 - EL4 |
| S1 + TW + S2 |
| S | = | 600.8 - 599.62 | = | 1.18 |
| 62 + 100 + 73.8 | 235.8 |
= 0.005 ft/ft = 0.5 percent
0.005 ft/ft = 0.5 percent
F3 = S x S1
F3 = 62 x 0.005 = 0.31 ft
6.2 + .31 = 6.51'
Ft = F1 + F3
Ft = 6.2 + 0.31 = 6.51 ft. (Length of horizontal projection of the culvert.) The upstream invert elevation to downstream invert elevation is-
LIP = S1 + TW = S2 + 2 ft
LIP = 62 + 100 + 73.8 + 2 = 237.8 ft; (Round up to 238 ft)
NOTE: These computations depict the cross section and figure 5-11 summarizes the calculations.
From these calculations, it has been determined that-
| (1) The actual length of the culvert is 235.8 feet. (2) A 2-foot projection is added because there is to be no downstream headwall. (3) The pipe must be rounded up to an even length of 238 feet. (4) This gives a culvert length of 238 feet for a single pipe. | |
| | The slope of the culvert is 0.005 ft/ft or 0.5 percent. |
| | The depth of fill at the critical section is 65 feet (rounded to the nearest tenth of a foot. |
STEP 4. Determine the largest pipe for the fill. Prepare a table as shown in table 5-4 and fill in all known values. Start by entering the largest pipe available, DP, into the table. Subtract DP from total fill, FT, to get fill critical, PC. FC represents the actual cover over the pipe at the critical section. Compare FC to cover required, CR.
Table 5-4. Unsubmerged inlet sample data
To find CR for aircraft, refer to table 5-1 which indicates that an SR-71C aircraft has a culvert weight type (WT) of 9. The CMP available is 10 gauge. With this information, refer to table 5-2 and select chart 9, corresponding to culvert WT 9. The diameters and cover are given in chart 9 under the 10-gauge line. Starting with the largest pipe available, 42-inch or 3.5 feet, CR is 4.0 feet (interpolated between pipe diameters.) Enter this value in table 5-4. The 42-inch pipe (3.5 feet) cannot be used because its actual cover is 3.01 feet against a required cover of 4.0 feet. Repeat the process using the next smaller pipe available, 36-inch pipe. It has a FC of 3.51 feet and a CR of 3.5 feet. This pipe will work.
STEP 5. Determine the culvert capacity and the number of pipes needed (side by side). Use table 5-3 to find the capacity and velocity for the 36-inch pipe.
The slope of the culvert is 0.5 percent. Entering the graph from the top (pipe diameter), move down the column until you intersect with the slope in the left-hand column. This will state the quantity of flow in the pipe. The velocity of flow is shown by following the respective shaded or unshaded areas down and to the left until it ends in the velocity column, 4 feet per second.
The 36-inch pipe has a capacity of 27.5 cubic feet per second for the 0.5 percent slope. The velocity indicated is 4 feet per second.
STEP 6. Determine the number of pipe required to carry the flow by dividing the total (Q) of 32 cubic feet per second (Step 1) by the pipe capacity, 27.5 cubic feet per second (Step 5), and
rounding up to the next whole pipe. For this example, the number of pipe required is 32/27.5 = 1.2 or two 36-inch diameter pipes.
STEP 7. The next step is determining the length of pipe to be ordered. The order length is calculated by multiplying NP (Step 6) times LIP (Step 3) times a waste factor (WF). Since pieces of material will be damaged in manufacturing, handling, transporting, and assembling, an additional amount over the actual in place length will be required. This value has been determined to be 15 percent of the total length of pipe required. For this project, the pipe selected will be 36 inches in diameter with a length in place of 238 feet. The length to order will be-
NP x LIP x WF
2 x 238 x 1.15 = 547.4 ft (round up to 548 ft)
The pipe comes in 2-foot increments; therefore, the value of 547.4 is rounded up to the next even value, or 548 feet of pipe.
PART G - DESIGNING A CULVERT FOR A ROADWAY
The procedure for designing a culvert for a roadway is much like that of designing a culvert for an airfield with one important difference: computing the pipe diameter.
To compute the pipe diameter for an airfield culvert, the calculation is based on aircraft loads, pipe gauges, and cover requirements. When making this determination in the field, you will rely on tables.
To compute the pipe diameter for a roadway culvert, determine the maximum diameter of a culvert that can be placed in the minimum fill section without the danger of crushing. This will determine the subsequent size of all culverts that can be used at that section without danger of crushing. Due to a difference in the application of loading, there will be a difference between the amount of cover required to protect culverts under vehicle and aircraft loadings.
The maximum pipe diameter used for roads or other systems carrying vehicle traffic is two-thirds of the minimum fill depth (Dmax= 2/3Fmin).
The following is a design method for a CMP under a roadway.
| Design Q - From the Rational Method. | |
| | Fill depth - From construction site. |
| | Slope - From elevations at top and bottom. |
| | Load (for airfields). |
| Dmax = 2/3Fmin. | |
| Tables (for airfields) |
| Np = Qdes divided by Qpipe | |
| | Qpipe is obtained from a pipe capacity table. |
| In place length = S1 (width of slope) + width of road (or runway) + S3 (width of other slope = __________ round up to next even number and add 2 feet, if no headwall downstream. | |
| | Order length = (In place length) (1.15). Round up to the next even number. |
GO TO: