Unit I: Legends,
| REPAIRING FLUSHOMETER VALVES Flushometer valves on water closets and urinals are automatic flushing valves. Over a period of time, a malfunction inside the valve or handle assembly can occur. When this happens, the malfunction is located and repaired. See figures 17, 18 and 19.
Figure 17. Diaphragm Flushometer Parts DIAPHRAGM-TYPE FLUSHOMETER VALVE MALFUNCTIONS AND REPAIRS
Figure 18. Piston Flushometer Parts PISTON-TYPE FLUSHOMETER VALVE MALFUNCTIONS AND REPAIRS
Figure 19. Flushometer Handle Parts FLUSHOMETER VALVE HANDLE MALFUNCTIONS AND REPAIRS
|