Main fuel pumps deliver a continuous supply of fuel at the proper pressure during operation of the aircraft engine. Engine-driven fuel pumps must be able to deliver the maximum flow needed at high pressure to obtain satisfactory nozzle spray and accurate fuel regulation.
Fuel pumps for turbojet engines are generally positive displacement gear or piston types. The term "positive displacement" means that the gear or piston will supply a fixed quantity of fuel to the engine for every revolution of the pump gears or for each stroke of the piston.
These fuel pumps may be divided into two distinct system categories constant displacement and variable displacement. Their use depends on the system used to regulate the flow of fuel. This maybe a pressure relief valve (barometric unit) for constant displacement (gear) pump or a method for regulating pump output in the variable displacement (piston) pumps.
Gear-type pumps have approximately straight-line flow characteristics, whereas fuel requirements fluctuate with flight or ambient air conditions. A pump of adequate capacity at all engine operating conditions will have excess capacity over most of the range of operation. This is the characteristic which requires the use of a pressure relief valve for disposing of excess fuel. The impeller, which is driven at a greater speed than the high-pressure elements, increases the fuel pressure from 15 to 45 psi, depending on engine speed.
This fuel is discharged from the boost element (impeller) to the two high-pressure gear elements. Each of these elements discharges fuel through a check valve to a common discharge port. High-pressure elements deliver approximately 51 gallons per minute at a discharge pressure of 850 psig.
Shear sections are incorporated in the drive systems of each element. If one element fails, the other element continues to operate. Check valves prevent circulation through the inoperative element. One element can supply enough fuel to maintain moderate aircraft speeds.
A relief valve is incorporated in the discharge port of the pump. This valve opens at approximately 900 psi and is capable of bypassing the total flow at 960 psi. Excess fuel is recirculated. The bypass fuel is routed to the inlet side of the two high-pressure elements.
The variable-displacement pump system differs from the constant-displacement pump system. Pump displacement is changed to meet varying fuel flow requirements; that is, the amount of fuel discharged from the pump; of variable flow, the applicable fuel control unit can automatically and accurately regulate the pump pressure and delivery to the engine.
Where variable-displacement pumps are installed, two similar pumps are provided and connected in parallel. Each pump can carry the load if the other fails during normal parallel operations. At times one pump may be insufficient to meet power requirements. Pump duplication increases safety in operation, especially during takeoff and landing.
The positive-displacement, variable-stroke-type pump incorporates a rotor, piston, maximum speed governor, and relief valve mechanism.
All gas turbine engines have several fuel filters at various points along the system. It is common practice to install at least one filter before the fuel pump and one on the high-pressure side of the pump. In most cases the filter will incorporate a relief valve set to open at a specified pressure differential to provide a bypass for fuel when filter contamination becomes excessive.
Paper Cartridge. This filter is usually used on the low-pressure side of the pump (Figure 4-1). It incorporates a replaceable paper filter element which is capable of filtering out particles larger than 50 to 100 microns (the size of a human hair). (One micron equals 0.000039 inch, or 25,400 microns equal one inch.) The cartridge protects the fuel pump from damage due to fuel contamination.

Screen Disc. This disc (Figure 4-2) is located on the outlet side of the pump. This filter is composed of a stack of removable fine wire-mesh screen discs which must be disassembled and cleaned periodically in an approved solvent.

Screen. This screen is generally used as a low-pressure fuel filter. Some of these filter screens are constructed of sinter-bonded stainless steel wire cloth and are capable of filtering out particles larger than 40 microns (Figure 4-3).

In addition to the mainline filters, most fuel systems will incorporate several other filtering elements. They may be located in the fuel tank, fuel control, fuel nozzles, and any other place deemed desirable by the designer.
The pressurizing and drain valve prevents flow to the fuel nozzles until sufficient pressure is reached in the main fuel control. Once pressure is attained, the servo assemblies compute the fuel-flow schedules. It also drains the fuel manifold at engine shutdown to prevent post-shutdown fires. But it keeps the upstream portion of the sure and delivery to the engine. system primed to permit faster starts.
Flow Divider. The pressurizing and dump valve used on some engines has a somewhat different function. In addition to the draining or dumping function, this unit also serves as a flow divider. At the beginning of an engine start, the fuel control supplies a pressure signal to the pressurizing and dump valve. This causes the valve to close the manifold drain and open a passage for fuel flow to the engine. On engine shutdown, fuel flow is cut off immediately by a valve in the fuel control. The pressure signal drops, the dump valve opens, and fuel drains from the manifold. The flow divider allows fuel to flow to the primary and secondary manifolds depending on fuel pressure. (See Figure 4-3.)
Pressure-Operated Valve. Some manufacturers, such as Allison and Lycoming, install a pressure-operated valve in the combustion chamber section. When the pressure in the burners drops below a specified minimum, usually a few pounds per square inch, this valve will open and drain any residual fuel remaining after a false start or normal shutdown. (Refer to Figure 4-4 to see where this drain valve fits into the system.)

Gas turbine engine fuel systems are very susceptible to the formation of ice in the fuel filters. When the fuel in the aircraft fuel tanks cools to 32°F or below, residual water in the fuel tends to freeze when it contacts the filter screen.
A fuel heater operates as a heat exchanger to warm the fuel. The heater can use engine bleed air, an air-to-liquid exchanger, or an engine lubricating oil, a liquid-to-liquid exchanger, as a source of heat.
A fuel heater protects the engine fuel system from ice formation. However, should ice form, the heater can also be used to thaw ice on the fuel screen.
In some installations the fuel filter is fitted with a pressure-drop warning switch which illuminates a warning light on the cockpit instrument panel. If ice begins to collect on the filter surface, the pressure across the filter will slowly decrease. When the pressure reaches a predetermined value, the warning light flashes on.
Fuel deicing systems are designed to be used intermittently. The system may be controlled manually by a switch in the cockpit or automatically using a thermostatic sensing element in the fuel heater to open or close the air or oil shutoff valve. An automatic fuel heater is illustrated in Figure 4-5.

On most gas turbine engines, fuel is introduced into the combustion chamber through a fuel nozzle. This nozzle creates a highly atomized, accurately shaped spray of fuel for rapid mixing and combustion with the primary airstream under varying conditions of fuel and airflow. Most engines use either the single (simplex) or the dual (duplex) nozzle.
Simplex Nozzle Figure 4-6 (A) illustrates a typical simplex nozzle. Its chief disadvantage is that it is unable to provide a satisfactory spray pattern in bigger engines because of the large changes in fuel pressures and airflows.

Duplex Nozzle. The chief advantage of the duplex nozzle is its ability to provide good fuel atomization and proper spray pattern at all rates of fuel delivery and airflow. At starting and low RPM and at low airflow, the spray angle needs to be fairly wide to increase the chances of ignition and good mixing of fuel and air. At higher RPM and airflow, a narrow pattern is required to keep the flame of combustion away from the walls of the combustion chamber (Figure 4-6[B]). The small fuel flow used in idling is broken up into a fine spray after being forced through a small outlet formed by the primary holes. The secondary holes are larger but still provide a fine spray at higher RPM because of the higher fuel pressure.
For the duplex nozzle to function, there must be a device to separate the fuel into low-(primary) and high( secondary) pressure supplies. This flow divider maybe incorporated in each nozzle, as with the single-entry duplex type (Figure 4-6[C]), or a single-flow divider may be used with the entire system (Figure 4-6[D]).
Single-entry duplex nozzles incorporating an internal flow divider require only a single fuel manifold (Figure 4-7). Dual-entry fuel nozzles require a double fuel manifold. Some dual fuel manifolds may not be apparent as such.

The flow divider, whether self-contained in each nozzle or installed in the manifold, is usually a spring-loaded valve set to open at a specific fuel pressure. When the pressure is below this value, the flow divider directs fuel to the primary manifold or nozzle orifice. Pressures above this value cause the valve to open, and fuel is allowed to flow in both manifolds or nozzle orifices.
Most modern nozzles have their passages drilled at an angle. The fuel is discharged with a swirling motion to provide low axial air velocity and high flame speed. In addition, an air shroud surrounding the nozzle cools the nozzle tip. It also improves combustion by retarding the accumulation of carbon deposits on the face. The shroud also provides some air for combustion and helps to contain the flame in the center of the liner (Figure 4-8).

Extreme care must be exercised when cleaning, repairing, or handling the nozzles. Even fingerprints on the metering parts may produce a fuel flow which is out of tolerance.
The engine fuel shutoff valve is installed in the main fuel supply line or tank outlet to the engine. It is controlled from the pilot's compartment. A fuel shutoff valve is usually installed between the fuel control unit and the fuel nozzles. When the throttle is placed in the closed position, this ensures positive shutoff of fuel to the engine.