T-700 CONTROL SYSTEM

The engine control system incorporates all control units necessary for complete control of the engine. The system provides for the more common functions of fuel handling, computation, compressor bleed and VG control, power modulation for rotor speed control, and overspeed protection. The system also incorporates control features for torque matching of multiple engine installations and overtemperature protection. The T-700 control system was designed for simple operation requiring a low level of pilot attention. The system performs many of the controlling functions formerly performed by the pilot. This has been done by providing:

t700.gif (21094 bytes)
Courtesy GE Aircraft Engines

Basic system operation is governed through the interaction of the electrical and hydromechanical control units. In general, the HMU provides for gas generator control in the areas of acceleration limiting, stall and flameout protection, gas generator speed limiting rapid response to power demands, and VG actuation. The ECU trims the HMU to satisfy the requirements of the load to maintain rotor speed, regulate load sharing, and limit engine power turbine inlet temperature.

Component Arrangement and Interconnection

Metering of fuel to the engine and basic engine control computations are performed in the hydromechanical control unit (Figure 4-18). The electrical and hydromechanical control units compute the fuel quantity to satisfy power requirements of the engine. The fuel and control system contains the following components:

--A separate signal to the overspeed and drain valve for NP overspeed protection.
--The required signals to an engine-mounted recorder to provide a record of engine operational history.
--The desired cockpit signals needed for proper engine operation.

For the T-700-GE-701/701A engines in a one engine inoperative (OEI) condition, the automatic contingency power switch, located in the ECU, resets the temperature limit amplifier to allow for more power is required for the operating engine.

Figure 4-19 lists the functional split between the two units mentioned above.

Fully integrated operation of the engine results from three inputs:

Hydromechanical Unit Operation

The HMU operates as a conventional gas generator power control when there is no input to the torque motor and with the load demand spindle set for maximum load (Figure 4-20). Engine schedules such as acceleration fuel flow and compressor VG position, are controlled by Ng and T2. The acceleration (or stall) limit is imposed by a maximum can schedule of Wf/P3 versus Ng and T2. A minimum flow schedule controls engine deceleration. Maximum and minimum metering valve stops provide absolute fuel-flow limits. An intermediate topping line controls maximum Ng speed. The topping line also limits excessive T4.5 in event of an electrical T4.5 control-system failure. Since these features are incorporated in the HMU, any power-available spindle motion will result in safe engine operation and will not cause engine damage. Except for intentional stopcocking of the control, no inadvertent shutdowns will occur from PAS motion.

A load-demand signal is introduced to the HMU through the LDS. When the LDS is reduced for its maximum setting with a reduction of aircraft rotor collective pitch setting the desired Ng is reset down from the prevailing PAS setting to provide immediate and accurate gas generator response. This new setting is trimmed by the ECU to satisfy the Np and load control functions established by the ECU.

The PAS sets a maximum available gas generator speed. The pilot usually sets this 120° PAS angle allowing the gas generator speed to reach a value which gives intermediate power. Through this collective pitch setting, the pilot positions the LDS to adjust available Ng to power level approximately equal to the rotor load demand power. The actual level of horsepower at 120° PAS angle will be more than required by the helicopter.

This is intentionally done for two reasons:

Electrical Control Unit Operation

The ECU, powered from an engine-mounted alternator (Figures 4-21, 4-22)--

 

Takeoff and Climb

Before takeoff, the PAS lever is advanced from ground idle to 120°, which is the normal flight position. This allows the rotor head to accelerate to 100 percent Np/Nr with the collective still in flat pitch. Ng will rise as the PAS is advanced but will cut back after the Np governing speed of 100 percent is reached. (Np governing can be selected at 95-101 percent, but 100 percent is considered standard.)

To take off, collective pitch is increased, increasing the torque load on the power turbine. Simultaneously, the LDS rotates, calling for an increase in gas generator speed to keep Np/Nr from falling below 100 percent. The ECUs of each engine perform a fine trim of fuel flow to match torques and trim Np/Nr to 100 percent.

As Ng increases, the HMU schedules the bleed valve closed and the variable stators open to increase airflow through the combustor and turbine.

If collective pitch is increased to a very high angle, TGT may approach the temperature limiting value. When this occurs, the ECU prevents any further increase in fuel to the engine. If torque load is increased further, Np/Nr will droop below 100 percent because power turbine governing must be sacrificed to protect the engine against overtemperature.

Cruise and Descent

At the end of the climb segment, less rotor lift is required and collective pitch is recked. The LDS rotates to reduce fuel flow and Ng; the variable stators will close slightly to optimize part-power fuel consumption and preserve stall margin.

Again, ECUs trim fuel flow. Upon entering a descent, the same sequence of events reduces Ng to the point that the bleed valve maybe opened. If the collective pitch is fully lowered, autorotation (power-off descent) is reached, and the torque drops to zero; overrunning clutches in the airframe transmission preclude a negative torque situation. Once the engines are uncoupled from the rotor, Nr is free to accelerate above 100 percent; and both engines will continue to govern Np at 100 percent. Nr and Np rotor speeds are held in reserve to pick up the rotor load when collective is again increased. This condition (100 percent Np zero torque) is known as flight idle.