CHAPTER 1
Principles of Electricity
1. We all use electrical equipment, such a lights, radio, television, electric stove and heaters, refrigerators, air conditioners and many more. We use these items many times a day and accept them as a matter of course. As long as the electrical equipment operates properly, we accept it with little concern about what actually takes place. Each of these devices operates because electric current flows through it.
2. To understand how electricity functions, you need to know the theory of electricity. The word "electric" is derived from the Greek word meaning "amber." The ancient Greeks used the word describe the strange force of attraction and repulsion that was exhibited by amber after it had been rubbed with a cloth. By knowing what electricity does, people have long ago developed theories which now are proving productive.
3. After centuries of experimentation by the world’s greatest scientists, laws by which electricity operates are becoming more widely known and better understood. Also, the world has arrived at a generally accepted theory of the composition of matter. Therefore you must learn about “matter” and certain magnetic effects exhibited by matter.
1. Electrical Fundamentals
1-1. Matter means all substance - solids, liquids, and gases. Today, the accepted theory is that matter is composed of three long-lived particles and many more short-lived particle. We are concerned only with one of the three long-lived particles - the electrons.
1-2. Electron Flow. Where there is a general movement of electrons in one direction, an electric current flows. The electrons together with protons (positively charged particles) and neutrons (neutral particles), make up atoms, of which all substances are composed. The protons and neutrons are in the nucleus (center of atom) and generally do not move about within a substance. The remainder of the atom is composed of electrons, which are in constant motion about the nucleus.
1-3. Electrons move at a high rate of speed in orbit around the nucleus and carry a negative charge. The electrons apparently do not bunch up as the protons do in the nucleus. An atom may be compared to our planetary system, with the sun as the nucleus and the earth and other planets representing the electrons. This is illustrated in figure 1, which shows the similarity between a hydrogen atom and our earth-sun system. More complex atoms have a larger nucleus and additional electrons. The electrons are considered to be relatively loose and are usually considered to be that which make up an electric current or flow.
Figure 1. Structure of atoms compared to earth and sun.
1-4. Electricity is often referred to as static electricity or dynamic electricity. A generator is said to produce dynamic electricity, and from this comes the word “dynamo” as another name for a generator. This is a machine which converts mechanical energy to electrical energy. Generally speaking, we are able to control dynamic electricity so that it is a useful force which we can put to work. A battery is also a source of dynamic electricity which we can control. The chemical action in a battery produces electrical energy which has three useful applications in an automobile. It drives the electric motor which starts the engine. It supplies energy to the spark plugs as heat for ignition, and the car lamps also use electrical energy for light. The car's generator recharges the battery and supplies the electric power when the engine is running. Generators and batteries are the most widely used sources of dynamic electricity. Now let's discuss static electricity and its effects.
1-5. The effects of static electricity can be observed in dry weather when you run a comb through your hair. The crackling you hear is the result of small discharges of electricity, and in a dark room you can see the tiny flashes of light a mirror. Lightning in a summer storm is the violent discharge of tremendous static charges.
A charge accumulates over a period of time, and when it becomes great enough to overcome the resistance of the air, a bolt of lightning occurs. Static electricity is the result of friction which dislodges enough electrons to form a charge. When the charge becomes very great, the accumulated energy is released in the form of electrical energy accomplished by lightning and thunder.
1-6. The next discussion will cover the three most common terms in electricity: “voltage,” “current,” and “resistance.” These three words are probably the most important in electrical fundamentals. If you understand the relationship between voltage, current, and resistance, you will have a good foundation on which to build your knowledge of electricity. Therefore, it is important that you learn the meaning of these terms. Since electricity cannot be seen, we will present visual comparisons to help you in understanding the relationships.
1-7. Voltage is one of the several terms which mean the same thing. These terms are: “voltage,” “potential,” “electromotive force (emf),” “potential difference,” and “electrical pressure.” The last term, “electrical pressure,” comes close to telling what voltage is. For example, the voltage of a battery is like water pressure in a hose when the nozzle is closed. This is called potential energy, not performing work. When the nozzle is opened, the water is forced out by the pressure, thus doing work. This may be related to closing an electrical switch, such as turning on your automobile lights. The potential energy of your battery is then released, performing the work of lighting the lights. The voltage is expended in the lights in the form of heat and light. Remember that voltage is electrical pressure.
1-8. The current flow is made possible by closing the switch which lowers the resistance to the voltage. Since this circuit has a relatively high resistance, the lamps could be burned for several hours before the battery would be discharged. The starter for the engine has a very low resistance, so it will draw a large current from the battery. It uses so much energy that the battery may become completely discharged by operating the starter for just a few minutes. This is reasonable because the starter is doing more work (converting electrical energy into mechanical energy) than are the car lights. With the foregoing discussion in mind, let us now consider concise definitions of our electrical terms.
Voltage is electrical pressure.
Current is the movement of electrons.
Resistance is the opposition to current flow.
1-9. Voltage is measured in volts. Current is measured in amperes. Resistance is measured in ohms. One volt is the electrical pressure required to cause 1 ampere of current to flow through a resistance of 1 ohm. Scientists have made experiments which show that 6280 trillion electrons pass a given point each second when there is 1 ampere of current in a circuit.
1-10. Resistance to electric current is present in all matter, but one material may have much more resistance than another. Air, rubber, glass, and porcelain have so much resistance that they are called insulators and are used to confine electricity to its proper circuit. The rubber covering on the wires to an electric lamp prevents the wires from touching each other and causing a short circuit. The rubber also protects a person who is using the lamp so that he does not receive an electric shock. Air acts as an insulator whenever a light switch is opened. Air fills the gap between the open contacts of the switch, and no current flows because of the high resistance. However, even air may at as a conductor if the voltage is high enough; otherwise, there could not be the electrical discharge which appears in a lightning strobe.
1-11. Metals are good conductors of electricity but some are better than others. Copper and silver are both good conductors of electricity because of their relatively low resistance. Aluminum is not as good, but is used for long overhead spans because of its light weight. Iron is a poor conductor, although it is used in combination with aluminum for added strength. Alloys of nickel and chromium are used in heater element to provide a specific resistance which passes enough current to heat the wires to a red glow. The alloy makes it possible to operate at high temperatures without melting. Copper is relatively cheap and a good conductor; it is the most widely used for wiring circuits.
1-12. The resistance of a copper wire is determined by three things: the cross-sectional area, the length, and the temperature. In normal temperature ranges the change in resistance is very small. The main factors of resistance are the area or cross section of a wire and its length. A wire with a larger diameter will have a greater cross-sectional area than will a smaller wire, and consequently less resistance. A long wire will have more resistance than a short one. Figure 2 shows the relationship between wire size and resistance. The first column gives the wire by number. A No. 40 wire is about the diameter of a hair. Sizes larger than No. 4/0 (spoken as four aught) are given in thousands of circular mil (350 MCM is 350,000 circular mils). The column at the right gives the resistance in ohms for 1000 feet of wire. One thousand feet of No. 10 copper wire has a resistance of about 1 ohm. The safe current carrying capacity is given in three columns which show the effects of insulation and conduit on the heat radiation ability of the conductor.
Figure 2. Copper wire size and resistance.
1-13. Magnet Characteristics. Magnetism related to electricity as heat is related to light. Whenever light is produced, we have heat; and wherever electricity is produced in the form of an electric current, we have magnetism. However, heat can be made without visible light and magnetism can be detected without an electric current. The effects of magnetism make a good starting place toward an understanding of electricity. Many of the fundamental laws can be demonstrated by simple experiments which you can perform for yourself.
1-14. A magnetic compass needle, a bar magnet, and some iron filings are the main things required. The compass needle will point toward the magnetic poles of the earth unless iron or steel objects are close enough to affect it. When the north pole of a bar magnet is brought close to the north pole of the compass needle, they will repel each other, as shown in figure 3; but there is a strong attraction between a north pole and a south pole. This illustrates the fundamental law of magnetism which says that like poles repel while unlike poles attract. Between two magnets there is a magnetic field made up of lines of force.
Figure 3. Attraction and repulsion between magnets.
1-15. This field around a magnet can be shown by placing a sheet of glass or paper over a bar magnet. As iron filings are sprinkled over the surface, they assume a definite pattern, as shown n figure 4. The magnetic field is strongest at the poles of the magnet, where the lines of force are bunched closely together. Lines of force follow a uniform distribution and never cross each other. A magnetic field may be distorted by iron or influenced by another magnetic field. A piece of soft iron will concentrate the lines of force in a field. In the same manner, two unlike poles brought near each other will have their fields linked up in common with each other.
Figure 4. Pattern of a magnetic field.
1-16. Lodestone is a natural magnet which has been known for many centuries. From it the first compass needles were fashioned. Artificial magnets are made by exposing metal to a strong magnetic field. Hardened iron will retain magnetism over a long period of time. Alloys of aluminum and nickel make even stronger magnets.
1-17. The relationship between electricity and magnetism can be demonstrated by a strong electric current passing through a conductor. If iron filings are sprinkled over a piece of cardboard, as shown in figure 5, they will show a pattern of rings surrounding the conductor. A sensitive compass held near the wire will line up at right angles to the wire, showing that the lines of force have a definite direction. The compass needle will swing around 180° if the current in the conductor is reversed. This requires direct current (dc) such as we get from a battery. The current from a battery is said to have only one direction, so it is called direct current. By reversing the connections of a circuit to a battery, the current in that circuit may be made to take the opposite direction.
Figure 5. Electric current produces magnetic field.
1-18. The magnetic field produced by a single straight conductor is relatively weak. However, the field can be concentrated by forming the conductor into a coil. In this form a coil carrying an electric current shows a magnetic pattern similar to that of a bar magnet. The coil develops a north pole at one end and a south pole at the other end. The polarity may be determined by the left-hand rule which states, “If the coil is grasped with the left hand with the fingers pointing in the direction of electron flow (negative to positive), then the thumb will point toward the north pole of the coil.” Electrons have a negative charge so they are attracted by a positive charge. Consequently, the electron movement in a circuit is from negative to positive. The electron movement in the conductor is indicated by two arrows figure 6.
Figure 6. Magnetic field produced by a coil.
1-19. Most coils are formed around an iron core because the core intensifies the magnetic field. The coil with its iron core is called a solenoid. Air offers resistance to the lines of force, which is called reluctance. Iron has less reluctance than air so that the lines of force will choose a path through iron rather than air when there is a choice. Forming the iron into the shape of a horseshoe makes less distance between the poles of a magnet, and the field is more concentrated. Soft iron is used for the core in electromagnets, as it will lose its magnetism when the current in the coil stops. The core is built up with thin sheets of soft iron which serve to insure the loss of magnetism when the magnetizing force is removed. An example of this is an electromagnet used for picking up and moving scrap iron in a salvage yard. The magnet is hung from a crane and may pick up a ten or more of iron at one time. When the load is moved into position to be dropped, the current to the coils is shut off. The loss of magnetism in the core allows the load to fall. The strength of the field of an electromagnet is determined by the number of turns of wire in the coils and the magnitude of the current.
1-20. Electron Movement and Effects. Electrons flowing through conductors cause several effects. We shall discuss some of these briefly.
1-21. Heat. Heat is generated as the electrons flow through the conductor. The electric coffeemaker, electric stove or heater, and such items are examples of this effect that we see each day. Light is a side effect of the heat generated.
1-22. Light. An incandescent lamp is made up of a filament (conductor) inclosed in an evacuated envelope. As current passes through the filament, it is heated to the point of glowing. If no air is allowed into the envelope, the filament will last a long time.
1-23. When electrons flow through an ionized gas at the right pressure and value, the gas will glow. Also, if a stream of electrons strikes certain compounds, the compounds will glow. Your TV picture gives a picture because of this effect.
1-24. Chemical. The chemical effect of electron movement is important. If electrons are forced to move through a solution of certain chemicals, one of the elements in the solution will come out of the solution in its natural state.
Thus, if an electric current is sent through a solution of copper sulphate, pure copper is deposited on one of the contacts immersed in the solution. A stream of electrons reaching a contact immersed in a solution can change the chemical makeup of the contact.
1-25. Magnetism. Magnetic field, identical to those discussed previously are produced as a direct result of electron movements within a conductor.
1-26. Electromagnetic Fields. The magnetic fields produced by electric currents are called electromagnetic fields and are composed of lines of force like all other magnetic fields. For example, in the field around a straight wire (conductor) carrying current the lines of force are concentric circles. The force of the field is strongest close to the wire, and it weakens rapidly the greater the distance from the wire.
1-27. To determine the direction of the magnetic field about a current-carrying wire, use the left-hand thumb rule which states, “Hold your left hand as if grasping the wire in such a way that your thumb points in the direction of the current (electron) flow. The fingers of your left hand will then point in the direction of the magnetic field about the wire.”
1-28. The magnetic field associated with a loop of wire is much the same as the field of a bar magnet. The loop has poles similar to those of a bar magnet, with lines of force emerging from the north pole and entering the south pole. The left-hand rule applied to the loop of wire will show you which is the north and which is the south pole.
1-29. If equal currents pass through a coil of wire consisting of 8 closely wound turns and through a single-turn loop of the same diameter as the coil, the magnetic fields will be almost identical in direction at every point. However, the magnetic field strength of the 8-turn coil will be approximately 8 times that of the single loop. This is because the fields of the 8 turns are virtually parallel to each other at every point and their effects are cumulative at every point.
1-30. If you spread out the 8 turns into a helical coil the magnetic field between the turns will be very weak. This is because the fields of adjacent turns will be opposite in direction and will tend to cancel each other. Inside and outside the coil they will be strong, for they will be cumulative. The net result will be a strong field of fairly uniform intensity, represented by nearly straight lines of force both inside and outside the coil.
1-31. Both of the coils, the one closely wound and the other spread apart, will each have a north pole at one end and a south pole at the other. The direction of the field will depend upon the direction of the current flow.
1-32. Safety. Anyone working with electricity must always be on his guard because of the dangers involved with electricity. Follow all rules. The basic rule is to keep clear of lines or equipment when they are energized. Do not put yourself in such a position that your body may become part of the circuit. Rules cannot be written to cover every situation; your own good judgment must govern your actions. The man who always practices safety will establish good working habits so that he will naturally do his work in a safe manner. The man who neglects safety is a menace to himself and to those working around him. Carelessness or a devil-may-care attitude should not be tolerated; either will eventually lead to the destruction of life or property.
1-33. Study the information in figure 7 so that you can recognize and identify each item. These symbols will be used in this chapter to make schematic diagrams of circuits. The purpose and application of these device will be explained in the discussion of circuits.
Figure 7. Basic electrical symbols.
1-34. An example of the use of symbols is shown in figure 8. The upper part shows a picture of a toaster, a percolator, and a hot plate. Each of these has a resistance element which converts electricity into heat when the appliance is plugged into an outlet. The lower part of the figure show how these items would be represented in a schematic diagram. Each item is shown by the same resistance symbol and must be identified with labels to distinguish which is which. Notice how much simpler the schematic diagram appears and yet it conveys the same information from an electrical standpoint as the more complex picture. You could easily draw the diagram in less than a minute and it would tell another technician the same story - that there were three appliances connected to a suitable source.
Figure 8. Comparison between picture and symbol representation.
2. Production of Electromotive Force
2-1. A generator is a machine which converts mechanical energy into electrical energy. First, the generator must have some source of mechanical energy. The type of machinery used to supply this energy to the generator is usually called the prime mover.
2-2. There are a number of methods used as prime movers. Water power (hydroelectric) normally has low operating costs, but high installation costs. Steam power (steam turbine) has a low installation and operating cost when used for plants of 15,000-kw capacity or more. Diesel engines are used a great deal h plants where the capacity required is from 2,000 w to 15,000 kw. However, there are low-speed and high-speed diesel engines. The high-speed diesel engine has a lower installation cost than the low-speed type, but its life is not as long. Gasoline engines should not be chosen to drive generators in plants which require continuous power because their fuel and maintenance costs are too high. The gasoline engines are usually used for small portable units.
2-3. The electrical power output from a generator may be either direct current (dc) or alternating current (ac), depending upon the construction. However, in principle, the rotating coils and the magnetic field through which they turn are the same for both types of generators. The primary difference between ac and dc generators is the method by which the current is taken from the machine.
2-4. In a generator we have two set of coils and a field: one set of coils is in motion and the other set of coils acts as an electromagnet to set up a magnetic field. Figure 9 shows how a conductor moving across a magnetic field has a voltage induced in it. The galvanometer connected to the conductor has the zero position of the pointer in the center of the scale so that it can read current in either direction. As the conductor is moved upward through the field, the galvanometer needle is deflected to the left. When the conductor is moved downward, the galvanometer needle is deflected to the right, showing that the direction of current in the conductor is reversed.
Figure 9. Inducing voltage by moving a conductor through a field.
2-5. Direct-Current Generator. A simplified diagram of a dc generator is illustrated in figure 10. A loop of wire represents the conductor that rotates in the magnetic field. The ends the loop terminate in two copper half rings which are insulated from each other. Fixed brushes make a contact with the copper to conduct electricity to the external circuit. The loop is rotated a clockwise direction. In position A, the lines of force are not being cut by the armature conductors but no voltage is produced. In position , with the black half of the armature conductor toward the north pole and the black half-ring against the negative brush, the armature conductor is cutting the maximum lines of force. At this position maximum voltage is induced into the armature conductors with the current flow through the galvanometer as indicated in figure 10. At position C, the armature conductor has rotated 180° from position A and again no voltage is produced. In position D, with the white half of the armature conductor toward the north pole and with the white half-ring against the negative brush, the armature conductor again is cutting the maximum lines of force, with maximum voltage being induced into the armature conductors and with the current flow through the galvanometer in the same direction as position B. Check the black brush in the figure at positions B and D and you will see that the sides of the armature conductor change but the brushes are stationary; they deliver direct current because either armature conductor in contact with the black brush will have the same direction of motion across the field.
Figure 10. Simplified diagram of a direct-current generator.
2-6. A direct-current generator is quite different from the working model shown in figure 10. Instead of permanent magnet, strong electromagnets are used. The strength of the field can be controlled by changing the current in the field coil A variable resistance in the field circuit makes it possible to control the voltage output of the generator. Instead of a single loop, there are many coils of wire in the rotor. The ends of each coil terminate in opposite copper segment. These copper segments are formed in a ring called the commutator. The rotor assembly illustrated figure 11 is an armature for a dc generator.
Figure 11. DC generator armature.
2-7. The ends of the armature shaft ride in bearings. The three main parts of a generator are the stator, the rotor, and the end bells. The main frame of the generator holds the stator or field. This frame supports the end bells which carry the bearings. One end bell contain the brush rig which holds the brushes. The voltage generated is controlled by a rheostat in the field circuit that changes the strength of the electromagnets. A change in speed would also change the voltage, but it is much simpler to control by resistance.
2-8. Alternating-Current Generator. A simplified diagram of an ac generator is shown figure 12. The difference between the dc generator and the ac generator is in the method used to deliver the current to the brushes. In the ac generator, sliprings are used instead of a commutator. This means that the same side of the loop delivers current to the same brush regardless of rotation; otherwise the operation is the same.
Figure 12. Simplified diagram of an alternating-current generator.
2-9. The illustration shows the loop turning in a clockwise direction. At position A, the lines of force are not being cut by the armature conductor so no voltage is produced. At position 3, the armature conductor is cutting the maximum lines of force, and the galvanometer indicates the direction of current flow by the needle pointing to the right. At position C, the galvanometer again shows zero because the lines of force are not being cut by the armature conductor. At position D, the armature conductor are again cutting the maximum lines of force, and the galvanometer again shows a current flow but in the opposite direction. What happened? At position B, the black side of the loop is moving down through the field and the black slipring is negative, sending current toward the meter. At position D, the black side of the loop is moving up through the field. Now the black slipring is positive. Current is directed from the white slip ring to the meter and back. The direction of current in the loop reversed itself and the same is true in the external circuit to the meter. The loop in the dc generator operated the same way but the commutator acted as a mechanical device to direct the current in only one direction to the external circuit.
2-10. The output frequency, or cycles, of an ac generator is determined by it speed and the number of poles. A two-pole machine must be driven at 3600 rpm to produce 60 cycles per second. A four-pole machine requires a speed of 1800 rpm for a frequency of 60 cycles. The formula for frequency is where f is the frequency, P is the number of poles, and S is the speed rpm. The output voltage is controlled in the same manner as described for a dc generator. A rheostat in series with the field is used to change the strength of the field magnet; the stronger the field, the greater the voltage generated.
![]()
2-11. The simple ac generator discussed here would produce single-phase current, as there is only one loop or winding. A three-phase generator requires three sets of windings and each winding produces one phase. The windings are physically displaced from each other 120° apart so that maximum voltage in one winding is generated at a different time from that in the other windings. At least three wires are needed to deliver three-phase electrical power from the generator to equipment. A single-phase voltage and current is developed between any two of the wires. Phases may be designated by number or as A, B, C, for identification. Figure 13 shows the pattern of a three-phase current for one complete cycle. A peak occurs every 60°, or 6 times for each cycle. The same pattern of rise and fall should be used to illustrate the cycle of three-phase voltage.
Figure 13. One cycle of a three-phase current.
3. Direct Current Fundamentals
3-1. In order for current to flow, two things are essential: there must be a source of electrical pressure (voltage) and there must be a complete circuit. The source of voltage may be a battery, a generator, or some other device. The complete circuit requirement means that there must be a complete path from the negative terminal through the load and back to the positive terminal of the source. The complete path should allow the electrons to flow freely to the load, do their work in the load, and then move freely back to the source.
3-2. However desirable this condition is, it cannot be completely achieved since no material used as a conductor (wire) allows the electrons to move with complete freedom. There is always some resistance to the electron flow. All conductors have some resistance; just how much they have depends on the size and length of the conductors as well as on the materials of which they are made.
3-3. The source of voltage is any device which has an excess of electrons in one place over the number of electrons in another place. Connecting the two places by means of an electrical circuit, including resistance, permits the two places to try to equalize the number of electrons. The movement of electrons that results from this attempt is what is known as current.
3-4. Ohm’s Law and DC Circuit. Since Ohm's law contains two separate thoughts, it may be expressed in the following two statements: (1) Current in any electrical circuit is directly proportional to the voltage, and (2) current in any electrical circuit i inversely proportional to the resistance. Ohm's law is more generally stated as follows: The current in a circuit is equal to the voltage divided by the resistance. Mathematically, it is expressed as:
|
|
(1) |
In this equation, I stands for the current in amperes, E for the voltage in volts, and R for the resistance in ohms. Thus, if the source of potential is a 6-volt battery and the electrical device is a bulb having 3 ohms of resistance, the current will be:
![]()
3-5. The equation for Ohm's law can be converted mathematically to read as follows:
|
E = I X R |
(2) |
By use of this equation, you can determine the voltage across a component of a circuit if you know the unit's resistance and the current flow through it. Thus, if you know that the current through a lamp is 2 amperes and the resistance of the amp is 3 ohm, you know that the voltage across it must be 3 X 2, or 6 volts.
3-6. The equation for Ohm's law can be converted mathematically in still another way to read:
|
|
(3) |
Using equation 3, you can determine the resistance of any circuit component if you know the voltage across it and the current flowing through it. Suppose you know that the voltage across a lamp is 6 volts and the current through it is 2 amperes. You can find the lamp resistance by substituting in equation 3:

3-7. Using these three equations enables you to find any one of the three quantities - voltage, current, or resistance - if you know the other two.
3-8. Series Circuits. A series circuit is one in which there is only one path through which the current can flow. In figure 14 three resistances and a battery are connected to form a series circuit. Since there is but one path for the current all of the current passes through each resistance and the current is the same throughout the entire circuit, or
It = I1 = I2 = I3, etc. (4)
3-9. The total voltage drop in the series circuit is equal to the sum of the voltages (voltage drops) across the individual resistors, or
Et = E1 + E2 + E3, etc. (5)
3-10. The total resistance of the circuit is equal to the sum of the resistances of the individual units, or
Rt = R1 + R2 + R3, etc. (6)
3-11. If one of the devices in a series circuit burns out, there is no longer a complete path for the current and, therefore, the other devices the circuit will not operate.
3-12. Problem: In figure 14, three resistances are connected in series across a 24-volt power source. The voltages and currents are measured and found to be as indicated in the illustration. Find:
a. The total voltage drop.
b. The total current.
c. The resistance of each unit.
d. The total resistance.
Figure 14. Series circuit.
Solution:
a. Using equation 5:
E = 8 + 12 + 4 = 24 volts
b. Using equation 4:
It = 4 = 4 = 4 amperes
c. Using equation 3, the resistance of each unit is computed as follows:

d. Using equation 6:
Rt = 2 + 3 + 1 = 6 ohms
Check:
Using equation 3, the total resistance can also be computed as follows:
![]()
3-13. Parallel Circuits. In a parallel circuit, two or more electrical devices provide independent paths through which the current may flow. The voltage across each device so connected in parallel is the same, or
Et = E1 = E2 = E3, etc. (7)
3-14. The total current in the circuit is equal to the sum of the individual currents flowing through the parallel-connected devices, or
It = I1 + I2 + I3, etc. (8)
3-15. Thus, the total amount of current in a parallel circuit is greater than the current in any one individual branch or leg, and consequently the total resistance must be less than the value of the smallest resistance in the circuit. The greater the number of electrical devices or resistors connected in parallel in a given circuit, the greater will be the total current, and the smaller will be the total resistance of the circuit.
3-16. Electrical devices are connected in parallel in any installation in order to: (1) decrease the total resistance of the circuit and (2) allow the units to operate independently of each other. In a parallel circuit, if one unit burns out it does not affect the operation of the other units; one path is broken but the other circuits are still complete.
3-17. There are several ways to calculate the total resistance of a parallel circuit. We shall show the simpler way first, which is the product over the sum method, and then give you the more complex general rule.
3-18. To calculate the total resistance of the parallel circuit shown in figure 15, use the following equation and solve for the equivalent resistance of only two paths at a time.
|
|
(9) |
Figure 15. Parallel circuit.
|
3-19. When the load units that are connected in parallel all have the same resistance value, the previous equation may be simplified to read:
|
|
(9A) |
3-20. Problem: In the illustration accompanying the previous discussion, three load units are connected in parallel. Using the resistance values indicated, find the total resistance.
Solution:
a. Using equation 9, for the first two paths

b. Since 3 ohms is the equivalent resistance of the first two paths you may substitute a 3-ohm resistor for them, and adding the 6-ohm resistor of the third path redraw the circuit as shown at the right in the illustration.
c. Then, combing R(1 and 2) with R3 and using equation 9 again, you have

3-21. The general equation for finding the total resistance in a parallel circuit is known as the reciprocal method. It involves determining the reciprocal of the sum of the reciprocals of the individual resistances. In other words, find a common denominator and divide the resistances into the common denominator, then add and invert, and divide this sum to find the total resistance.
|
|
(10) |
3-22. Using equation 10, the total resistance can be computed as follows:

3-23. Series-Parallel Circuit. As shown in figure 16, in a series-parallel circuit some of the units are connected in series with each other, while other units are connected in parallel. To solve a series-parallel problem, first convert it to a series circuit by substituting an equivalent resistance for the parallel resistances; then solve the series circuit problem as explained previously.
Figure 16. Series-parallel circuit.
3-24. Problem: In the illustration of the series-parallel circuit a resistor is connected in series with four lamps which are connected in parallel with each other. The voltage and resistances were measured and found to be as indicated. Find the current through the various parts of the circuit.
Solution:
a. The resistance of each lamp is 4 ohms. Therefore, using equation 9A, the equivalent resistance of the four lamps in parallel is
![]()
b. Substituting a 1-ohm resistor for the four lamps and using equation 6, you find the total resistance of the circuit as follows:
R4 = 5 + 1 = 6 ohm
c. Using equation 1, you compute the total current in the circuit to be
![]()
d. Since the total current must flow through the series resistor, the current flow through it must be 4 amperes.
e. Since the total current flowing through the four lamps is 4 amperes and since they all have the same value of resistance, the current must divide evenly among the lamps and is therefore found to be 1 ampere through each lamp circuit.
3-25. Power.
Besides the current, voltage, and resistance of a circuit, the power must
also be considered. Power is defined as the rate of doing work, and it is
measured in a variety of units. An electric motor, for example, is rated in
terms of horsepower. One horsepower is the rate of doing work when a
550-pound weight is raised a distance of 1 foot in 1 second. Some motors
develop 5000 or more horsepower. Electrical power is generally expressed in
terms of watts. A watt is the power consumed in a circuit through which 1
ampere flows under a pressure of 1 volt. One horsepower equals 746 watts.
3-26. Most electrical devices are rated according to the voltage that should be applied to them and also according to the amount of power they require. For example one lamp might be rated as a 115-volt, 40-watt lamp, while another might be rated as a 115-volt, 20-watt lamp. This means that both lamps are to be operated on a 115-volt circuit, but that twice as much power is required to operate the first lamp as the second.
3-27. You can compute the wattage of an electrical unit - that is, the power it requires - by multiplying the value of the current flowing through it by the value of the voltage applied to it.
P = I X E (11)
Thus, a starter motor drawing 70 amperes at a potential of 24 volts is using 1680 watts of electrical power. To convert electrical power (wattage) to horsepower, divide the electrical power rating by 746. Thus, by dividing 1680 watts by 746-watts (the electrical equivalent of 1 horsepower) you will find that the starter motor will develop approximately 2.25 horsepower.
4. Alternating-Current Fundamentals
4-1. In a dc circuit, current moves in one direction, from the negative terminal of the source through the circuit to the positive terminal. In ac circuits, the current flows first in one direction and then in the opposite direction, thus the name “alternating current.”
4-2. Alternating current has largely replaced direct current for a number of reasons, namely: (1) ac voltages can be increased or decreased very efficiently with transformers, (2) ac devices are much simpler and consequently are less prone to trouble than are dc devices, (3) ac units are much lighter, and (4) they operate more efficiently.
4-3. Most electrical appliances manufactured in the United States have a small “data plate” which gives the electrical information necessary for connecting the appliances to the proper electrical circuits. This data plate usually gives the voltage, frequency (cycles per second), horsepower (size of motor) or watts (for heating units), amperes, ac or dc, and the power factor. If you connect electrical appliances per the information on the data plate, they usually give a long life of uninterrupted service.
4-4. Phase of Current and Voltage. When current and voltage pass through their zero value and reach their maximum value at the same time, the current and voltage are said to be in phase. If the current and voltage pass through zero and reach their maximum values at different times, the current and voltage are said to be out of phase. In a purely inductive circuit the current reaches a maximum value later than the voltage, lagging the voltage by 90°, or one-fourth of a cycle. In a circuit containing only capacitance, the current reaches its maximum ahead of the voltage, and the current leads the voltage by 90°, or one-fourth of a cycle.
4-5. Figure 17 shows graphically the in-phase condition and the effect of inductance and capacitance on this phase relationship. The current will never lead or lag the voltage by exactly 90° because of the resistance of the conductor. The number of degrees by which the current leads or lags the voltage in a circuit depends on the relative amounts of resistance, capacitance, and inductance in the circuit.
Figure 17. Sine wave of current and voltage.
4-6. Inductance. When an alternating current flows through a coil of wire, it sets up an expanding and collapsing magnetic field about the coil. The expanding and collapsing magnetic field induces a voltage within the conductor proper which is opposite in direction to the applied voltage.
4-7. This induced voltage opposes the applied voltage, thus serving to lessen the effect of the applied voltage. This results in the self-induced voltage tending to keep a current moving when the applied voltage is decreasing and to oppose a current when the applied voltage is increasing. This property of a coil which opposes any change in the value of the current flowing through it is called inductance.
4-8. The inductance of a coil is measured in henrys, and the symbol for inductance is L. In any coil the inductance depends on several factors, principal of which are the number of turns of wire in the coil, the cross-sectional area of the coil, and the material in the center of the coil, or the core. A core of magnetic material greatly increases the inductance of the coil.
4-9. Remember, however, that even a straight wire has inductance, small though it may be when compared to that of a coil. All ac motors, relays, transformers, and the like contribute inductance to a circuit.
4-10. Capacitance. Another important property of ac circuits, besides resistance and inductance, is capacitance. While inductance is represented in a circuit by a coil and resistance by a resistor, capacitance is represented by a capacitor. Any two conductors separated by a nonconductor constitute a capacitor. The capacitor is used in an electrical circuit to momentarily store electricity, smooth out pulsating dc, give more torque to a motor by causing the current to lead the voltage (see fig. 17), reduce arcing of contact points, and hasten the collapse of the magnetic field of an ignition coil to produce a hotter spark.
4-11. Power in AC Circuits. In a dc circuit, we calculate power by using equation 11, where the volts times the amperes equal the watts (power). Thus, if 1 ampere flows in a circuit at a potential of 200 volts, the power is equal to 200 watts. The product of the voltage and the amperage is the true power of the circuit in this case.
4-12. In an ac circuit, however, the voltmeter indicates the effective voltage and an ammeter indicates the effective current. The product of these two indicate what is called apparent power. The relationship between true power, reactive power, and apparent power is shown graphically in figure 18. Only when the ac circuit is made up of pure resistance is the apparent power equal to the true power.
Figure 18. Power relations in an ac circuit.
4-13. When there is capacitance or inductance in the circuit, the current and voltage are not exactly in phase with each other, and the true power is less than the apparent power. The true power is obtained by a wattmeter indication. The ratio of the true power to the apparent power is called the power factor of the load and is usually expressed as a percentage. In equation form the relationship is:
|
|
(12) |
4-14. Problem: A 220-volt motor draws 50 amperes from the supply lines, but the wattmeter indicates that only 9350 watts are taken by the motor. What is the apparent power and what is the power factor of the circuit?
Solution:
a. Apparent power = 220 X 50 = 11,000 volt-amperes.
b. Using equation 12,

5. Transformers
5-1. A transformer is an apparatus which transforms electrical energy at one voltage into electrical energy at another voltage. It consists of two coils which are not electrically connected (except auto transformers) but are arranged so that the magnetic flux surrounding one coil cuts through the other coil upon buildup or collapse of the magnetic field. When there is an alternating current in one coil, the varying magnetic flux creates an alternating voltage in the other winding by mutual induction. A transformer will also operate on pulsating dc but not on pure dc.
5-2. A transformer consists of three primary parts: an iron core, which provides a circuit of low reluctance for the magnetic flux; a primary winding, which receives the electrical energy from the supply source; and a secondary winding, which receives electrical energy by induction from the primary and delivers it to the secondary circuit.
5-3. The primary and secondary coils are usually wound, one upon the other, on a closed core obtain maximum inductive effect between them. The turns of insulated wire and layers of the coil are well insulated from each other by layers of impregnated paper or mica. The iron core is laminated to minimize magnetic current losses (eddy losses) and is usually made of specially prepared silicon steels since these steels have a low hysteresis loss. (Hysteresis loss is the portion of the magnetic energy converted to heat and lost to the system so far as useful work is concerned. It occurs with changing magnetic polarity.)
5-4. There are two classes of transformer - voltage transformers for stepping up or stepping down voltages, and current transformers which are generally used in instrument circuits. In voltage transformers the primary coils are connected in parallel across the supply voltage, as seen in figure 19. In current transformers the primary windings are connected in series in the primary circuit.
Figure 19. Voltage and current transformer.
5-5. Of the two types, the voltage transformer is the more common. There are also power-distributing transformers for use with high voltages and heavy loads. Transformers are usually rated in kilovolt-amperes.
5-6. Principles of Operation. When an alternating voltage is connected across the primary terminals of a transformer, an alternating current will flow and self-induce in the primary coil a voltage which is opposite and nearly equal to the connected voltage. The difference between these two voltages will allow just enough current to flow in the primary coil to magnetize its iron core. This is called the exciting (magnetizing) current.
5-7. The magnetic field caused by the exciting current cuts across the secondary coil and induces a secondary voltage by mutual induction. If a load is connected across the secondary coil of the transformer, the load current flowing through the secondary coil will produce a magnetic field which will tend to neutralize the magnetic field produced by the primary current. This, in turn, will reduce the self-induced (opposition) voltage in the primary coil and allow more primary current to flow.
5-8. The primary current increases as the secondary load current increases, and decreases as the secondary load current decreases. When the secondary load is removed, the primary current is again reduced to the small exciting current sufficient only to magnetize the iron core of the transformer.
5-9. Connecting Transformers in an AC Circuit. Before studying the various uses of transformers and the different ways of connecting them, you should understand the difference between a single-phase circuit and a three-phase circuit.
5-10. A single-phase circuit is a circuit in which the voltage is generated by an alternator, as shown in figure 20. This single-phase voltage may be taken from a single-phase alternator or from one phase of a three-phase alternator, as explained later.
Figure 20. Single-phase generator and load.
5-11. A three-phase circuit is a circuit in which three voltages are generated by an alternator with three coils so spaced within the alternator that the three voltages generated are equal but reach their maximum values at different times, as shown figure 21. In each phase of a 60-cycle, three-phase generator, a cycle is generated every 1/60 second.
Figure 21. Sine wave of voltage outputs of single- and three-phase generators.
5-12. In its rotation, the magnetic pole passes one coil and generates a maximum voltage; one-third of a cycle (1/180 second) later, this same pole passes another coil and generates a maximum voltage in it; and one-third of a cycle later, it passes still another coil and generates a maximum voltage in it. This causes the maximum voltages generated in the three coils always to be one-third of a cycle (1/180 second) apart.
5-13. Three-phase motors and other three-phase loads are connected with their coils or load elements arranged so that three transmission lines are required for delivery of power. (See fig. 22.) Transformers that are used for stepping the voltage up or down in a three-phase circuit are electrically connected so that power is delivered to the primary and taken from the secondary by the standard three-wire system.
Figure 22. Three-phase generator with three conductors.
5-14. However, single-phase transformers may be connected across any two phases of a three-phase circuit, as shown figure 23. When single-phase loads are connected to three-phase circuits, the loads are distributed equally among the three phases in order to balance the loads on the three generator coils.
Figure 23. Step-down transformer, two-wire system.
5-15. Another use of the transformer is the single-phase transformer with several taps in the secondary. With this type of transformer, we can lower the voltage and also have several working voltages, as shown in figure 24. A center-tapped transformer powering a motor requiring 220 volts, along with for lights requiring 110 volts is shown in figure 25. The motor is connected across the entire transformer output, and the lights are connected from the center tap to one end of the transformer. With this connection we are using only half of the secondary output.
Figure 24. Multivoltage transformer secondary.
Figure 25. Step-down transformer, three-wire system.
5-16. This type of transformer connection is used quite extensively because of the combinations of voltages that may be taken from one transformer. Various voltages may be picked off the secondary winding of the transformer by inserting taps (during manufacture) at various points along the secondary winding. The various amounts of voltage are obtained by connecting to any two taps or to one tap and either end, as shown a previous illustration.
5-17. Transformers for three-phase circuit can be connected in any one of several combinations of the wye (y) and delta (D) connections. The connection used depends on the requirements for the transformer.
5-18. Wye connection. When the wye connection is used in three-phase transformers, a fourth or neutral wire may be used, as show in figure 26. The neutral wire serves to connect single-phase equipment to the transformer. Voltages (120 v) between any one of the three-phase lines and the neutral wire can be used for power for devices such as lights or single-phase motors. Single- and three-phase equipment can be operated simultaneously, as show in figure 27.
Figure 26. Wye-to-wye connection.
Figure 27. Four-wire, three-phase wye system.
5-19. In combination, all four wires can furnish power at 208 volts, single and three-phase, for operating single- and three-phase equipment such as motors or rectifiers with the center tap used as equipment ground. When only three-phase equipment is used, the ground wire may be omitted. This leaves a three-phase, three-wire system.
5-20. Delta connection. Figure 28 shows the primary and secondary with a delta connection. Between any two phases the voltage is 240 volts. This type of connection using the three wires - A, B, and C - can furnish 240-volt, three-phase power for the operation of three-phase equipment.
Figure 28. Delta-to-delta connection.
5-21. Wye and delta connections. The type of connection used for the primary coils may or may not be the same as the type of connection used for the secondary coils. For example, the primary may be a delta connection and the secondary a wye connection. This is called a delta-wye (D-y) connected transformer. Other combinations are delta-delta, wye-delta, and wye-wye.
5-22. Current Transformers. Current transformers are used in ac power supply systems.
5-23. The current transformer is a ring type transformer using a current-carrying power lead as a primary (either the power lead or the ground lead of the ac generator). The current in the primary induces a current in the secondary by magnetic induction.
5-24. The sides of all current transformer are marked “H1” and “H2” on the unit base. The transformers must be installed with the “H1” side toward the generator in the circuit in order to have proper polarity. The secondary of the transformer should never be left open while the system is being operated; to do so could cause dangerously high voltages and could overheat the transformer. Therefore the transformer output connections should always be connected with a jumper when the transformer is not being used but is left in the system.
6. Electrical Meters
6-1. In the installation, inspection, maintenance, and operation of electrical air-conditioning equipment, you will often have to measure voltage, current, and resistance. A number of instruments have been developed for this purpose.
We will discuss these meters and their uses.
6-2. Galvanometer. In electrical systems the moving-coil galvanometer (D'Arsonval type) is used quite extensively. This movement is used in such instruments as voltmeters, ammeters, thermocouple thermometers, and electrical tachometer.
6-3. Voltmeter. A voltmeter is an instrument used to measure the difference in electrical potential, or the voltage, between two point. (See fig. 29.) Notice in figure 29 the rotary switch which may be connected to various size resistors. These are in series with the movable coil to limit the amount of current flow through the meter circuit. If an unmarked voltage is to be measured, set the rotary switch to the highest resistance and work down until the meter reads in a somewhat mid-position of full scale.
Figure 29. Voltmeter.
6-4. Ammeter. An ammeter is an instrument that measures the amount of current flowing in a circuit. You may have a need for an ammeter with a range from a milliampere to 500 amperes. These meters may have an external shunt, as shown in figure 30, or they may be internally shunted. Question: What is a shunt for? Answer: Very fine wire is used in the coil. This wire can carry very little current without overheating - only a small fraction of an ampere. A low-resistance shunt is connected in parallel with the meter so that most of the current bypasses the meter; only a very small portion of the total current flows through the coil. For example: When a 300-ampere ammeter and a 300-ampere shunt are connected into a circuit carrying 300 amperes, only 0.01 ampere flows through the meter to give full-scale deflection; the remaining 299.99 amperes flow through the shunt.
Figure 30. Ammeter with an external shunt.
6-5. By applying the basic rule for parallel circuits, you can easily compute the value of a shunt resistor needed to extend the range of an ammeter.
6-6. Ohmmeter. An ohmmeter is an instrument used to measure resistance in ohms. Combination voltohmmeters and other multipurpose meters are used more than simple ohmmeters. The principle of operation of an ohmmeter is basically the same, regardless of whether the meter is a separate instrument or is part of a multipurpose instrument.
6-7. An ohmmeter contains a very sensitive galvanometer. The scale on the dial is calibrated in ohms. Maximum current flows through the circuit when there is a minimum amount of resistance between the ohmmeter terminals. For this reason, zero is at the right-hand end of the scale. The ohmmeter does not have an evenly, graduated scale; frequently the right half of the scale will read to about 5000 ohms, while the left half will read 100,000 ohms or more. The left-hand end of the scale is sometimes marked “INF,” which means there is infinite resistance between the terminals.
6-8. Some ohmmeters have three or even four posts to which the leads may be attached. (See fig. 31.) These posts may be marked in different ways on different meters, but for purposes of explanation let us consider a meter on which the posts are marked “C,” “RX1,” “RX10,” and “RX100.” If the leads are connected to C and RX1, the resistance being measured is indicated directly on the scale. If the terminals are connected to C and RX10, the reading on the scale must be multiplied by 10 to give the actual resistance. If the terminals are connected to C and RX100, the reading on the scale must be multiplied by 100. Short the two leads together and zero the meter with the zero adjustment. This must be done any time the lead is moved from one jack to another.
Figure 31. Ohmmeter.
CAUTION: Make sure the circuit to be measured is dead before using the ohmmeter.
6-9. Rectifier Meter. Alternating-current voltages are often measured by rectifier type meters. A rectifier meter is actually a dc meter with a rectifier added to change the ac to dc. Without a rectifier, of course, a dc meter would give no indication when applied to an ac circuit. Generally, a copper-oxide rectifier connected as a bridge provides the rectification. This is shown in figure 32. Values of ac voltages indicated on the rectifier meter are effective values.
Figure 32. Rectifier meter circuit.
6-10. Wattmeters. Power in an ac circuit is not always found by multiplying voltage by amperage as in a dc circuit. Such a power computation can be made for ac circuit only when the voltage and current are in phase, that is, when there is a purely resistive load. In practice this condition seldom exists, since in almost all ac circuits the load is reactive because of the presence of inductance and capacitance. The wattmeter, however, measures the true power consumed in a circuit by all electrical devices regardless of the type of load.
6-11. Wattmeters may be used to measure power consumed in either single-phase or three-phase circuits in which the load is balanced. The single-phase wattmeter has a high-resistance moving voltage coil for many turns of fine wire and stationary coils, called current coils, of low resistance with a few turns of heavy wire. Connect the current coils in the line in series with the load, and the voltage coil across the line.
6-12. A single-phase wattmeter may be connected to measure the power by a three-phase circuit. To do this, connect the current coil in one load line and the voltage coil between the line and ground. This will give the power in one phase. Multiply this by 3 to get the total power.
6-13. Three-phase wattmeters consist of two or more single-phase movement with all the moving elements mounted on one shaft. Separate single-phase wattmeters can be used to measure power in three-phase circuits by connecting two wattmeter in any two of the three phases. In this case, add the two wattmeter readings if the power factor of the load (motor) is greater than 50 percent (the power actor can be found on the nameplate or in the technical order). If the power factor is below 50 percent, the power input to the load (motor) is the difference between the two readings.
6-14. You can determine whether to add or subtract the readings by the following: If both of the scale pointers deflect toward the top of the scale, add the readings; if one tends to indicate a negative value, reverse either the voltage or current connections and subtract the reading of one wattmeter from the reading of the other.
6-15. Using Electrical Meters. Only two of the meters discussed in this chapter, the voltmeter and the ohmmeter, are used to locate troubles in an electrical circuit. How the meters are used for this purpose will be explained in detail. However, before attempting to use any of the meters which have been discussed, you should fix firmly in your mind certain precautions concerning their use.
6-16. General precautions.
(1) Never connect a voltmeter to a circuit having a voltage that exceeds the voltmeter scale. If the voltage is unknown, start with a high scale and work down until you get the correct one.
(2) Never connect an ammeter into a circuit carrying more current than the maximum reading on the scale of the meter.
(3) Always connect an ammeter in series with the units in the circuit.
(4) Never connect an ammeter across the terminals of a battery or generator, or any other place where you provide a path through the meter from a source of voltage direct to ground. To do so would cause the meter to burn out immediately.
(5) Always check the rating of a meter before you use it.
(6) Never use an ohmmeter to check an electrical circuit until the source of voltage has been disconnected from all parts of the circuit to be checked. Using the ohmmeter in a live circuit would damage the meter.
(7) Always connect the voltage coil of a wattmeter to the supply side of the current coil.
6-17. Voltmeter. The most common trouble found in electrical circuits that are inoperative is an open circuit. This means simply that there is not a complete path for the current to flow through as it should. The “open,” or the place where the circuit is open, can be located with either a voltmeter or an ohmmeter. If electrical power is available, use the voltmeter.
6-18. An open in a circuit may be located anywhere in the circuit. It my be in the switch, fuse, wiring, or in the unit itself. If the fuse is burned out, or open, you should inspect all of the circuit to determine what caused the fuse to blow.
6-19. A trouble known as a short might have caused the fuse to blow. A short is direct contact between the hot and negative or ground portion of the circuit. Since there is practically no resistance in this new or short circuit, the current flow increases immediately until it exceeds the capacity of the fuse and blows the fuse.
6-20. A voltmeter is always connected in parallel with the unit being tested - that is, across the unit - or to the points between which the difference of potential is to be measured.
6-21. If you should accidentally connect the voltmeter in series with the circuit, it wouldn't hurt the mete because the high resistance in the meter would limit the current flow. However, the units in the circuit would not operate because of the low current.
6-22. Locating an open with a voltmeter is simply a matter of checking to see how far voltage is present in the circuit. Voltage will be present the circuit right up to the point where the circuit is open.
6-23. When you have to check a circuit to find an open, you can start at any point in the circuit. It is logical, of course, to check the fuse first and the unit second. As explained earlier, this will enable you to tell whether the trouble is an open or a short.
6-24. If the fuse and the unit are both good, you may have to check each end of each length of wire in the circuit to find the open. Use the wiring diagram of the circuit as a guide. The important things are to know what voltage reading you should have at each point in the circuit and to recognize an abnormal reading when you get one. Figure 33 shows the voltage readings obtained at different points in a circuit with an open fuse, an open lamp filament, and one with an open ground wire.
Figure 33. Continuity testing with a voltmeter.
6-25. Ohmmeter. Before you use an ohmmeter to check a circuit, be sure there is no electrical power in the circuit. It was explained earlier in this chapter that using an ohmmeter in a live circuit could damage the meter.
6-26. If you use a multirange ohmmeter to check resistance, choose a scale on the ohmmeter which you think will contain the resistance of the element you are going to measure. In general, select a scale in which the reading will fall in the mid-scale range. Short the leads together and set the meter, with the zero adjustment, to read zero ohms. If for any reason you change scales, readjust the meter to zero ohms.
6-27. Connect the leads across the circuit. Infinite resistance indicates an open circuit. A reading other than infinite resistance indicates continuity.
6-28. Let's simulate locating the troubles with the ohmmeter. First we must be sure we have disconnected the power from the circuit to permit use of the ohmmeter. Now, with one lead connected to negative or ground, check at various points with the other lead. If you start at the point where the circuit is grounded, the meter will read zero ohms.
6-29. After you pass the first resistance the meter will read that resistance. When you get the first reading of infinite resistance, this will indicate that the open is between that point and the point where you got the last normal reading.
6-30. When you check continuity in a parallel circuit, isolate the unit you are checking so the ohmmeter will not show the resistance of parallel paths.
7. Motors
7-1. In this section we will discuss some of the electrical motors that you may encounter in your job. We will discuss ac single and polyphase induction motors, ac/dc universal motors, and synchronous motors.
7-2. Principles of Operation. The speed of rotation of an ac motor depends upon the number of poles and the frequency of the electrical source of power:
![]()
7-3. Since an electrical system operates at 60 cycles, an electric motor at this frequency operates about 2 1/2 times the speed of the old 25-cycle motor with the same number of poles. Because of this high speed of rotation, 60-cycle ac motors are suitable for operating larger refrigeration systems.
7-4. Alternating-current motors are rated in horsepower output, operating voltage, full-load current, speed, number of phases, frequency, and whether they operate continuously or intermittently.
7-5. Single-Phase Induction Motors. All single-phase induction motors have a starting winding (see fig. 34) since they cannot be started with only the single-phase winding on the stator. After the motor has started, this winding may be left in the circuit or be disconnected by a centrifugal switch.
Figure 34. Single-phase motor with capacitor starting winding.
7-6. Both single-phase and three-phase motors operate on the principle of a rotating magnetic field. As a simple example of the principle of the rotating field, imagine a horseshoe magnet held over a compass needle. The needle will take a position parallel to the magnetic flux passing between the two poles of the magnet. If the magnet is rotated, the compass needle will follow.
7-7. A rotating magnetic field can be produced by a two- or three-phase current flowing through two or more groups of coils wound on inwardly projecting poles of an iron yoke. The coils on each group of poles are wound alternately in opposite directions to produce opposite polarity, and each group is connected to a separate phase of voltage.
7-8. You can understand this action with the aid of figure 35, which shows a four-pole stator field energized by two windings connected to two separate phase voltage. Winding No. 1 of the motor is 90° out of phase with winding No. 2, which causes the current in winding No. 1 to lead the current in winding No. 2 by 90°, or by 1/240 second, assuming the frequency of the ac power supply is 60 cycles per second. Winding No. 1 can be referred to as phase 1, and winding No. 2 as phase 2.
Figure 35. Production of a rotating magnetic field.
7-9. The direction of the magnetic field is indicated by a magnetic needle (considered as a north pole for clarity). The needle will always move to a position where it will line up with the magnetic flux passing from pole to pole. Notice the phase relationship of the two voltages which are applied to the two phase windings of the field. Phase 1 supplies current to the coils on poles A and A', and phase 2 supplies current to the coils on poles B and B'. The two currents are 90° out of phase, with phase 1 leading.
7-10. At position B, the current in phase 1 at a maximum and the poles of A and A' are fully magnetized. The poles of coils B and B' are not magnetized, since the current in phase 2 is zero. Therefore the magnetic needle points in the direction shown. At position C, the current coils A and A', phase 1, has decreased to the same value to which the current in coils B and B', phase 2, has increased. Since the four poles are now equally magnetized, the strength of the field is concentrated midway between the poles, and the magnetic needle take the position shown.
7-11. At position D, the current of phase 1 is zero through coils A and A', and there is no magnetism in these coils. There is maximum current through coils B and B', the magnetic field strength of B and B' is maximum, and the magnetic needle takes the crosswise position. This action is repeated during successive cycles of the flow of the alternating currents, and the magnetic needle continues to revolve in the same direction within the field frame as long as the two phase currents are supplied to the two sets of coils.
7-12. In an induction motor with two poles for each phase winding, the north pole would glide from one pole to the other in 1/120 second and make a complete revolution in 1/60 second, which would be at the rate of 3600 rpm. If the compass needle is replaced by an iron rotor wound with copper bar conductors (usually called a squirrel-cage rotor because the conductors resemble a squirrel cage, as shown in figure 36, a secondary voltage is induced in the conductors by mutual induction much in the manner that the secondary voltage is developed in a transformer.
Figure 36. Squirrel-cage induction-motor rotor.
7-13. Current flowing in the conductors produces a magnetic field which reacts on the rotating magnetic field and causes a rotation of the iron core similar to the rotation of the magnetic needle. The direction of rotation may be reversed by reversing the connections of one phase.
7-14. Shaded-pole motor. The stator windings of a shaded-pole motor differ from other single-phase motors by definitely projecting field poles (fig. 37). A low-resistance, short-circuited winding or copper band is placed across one tip of each pole, from which the name “shaded-pole” is derived. As the current increases in the stator winding, the flux increases. A portion of this flux cuts and induces a current in the shaded winding. This current sets up a flux which opposes the flux inducing the current; therefore, most of the flux passes through the unshaded portion of the pole, as shown in figure 38.
Figure 37. Shaded pole motor stator windings.
Figure 38. Flux path in a shaded-pole motor.
When the current in the winding and the main field flux reaches a maximum, the rate of change is zero, so no electromotive force is induced in the shaded winding. A little later the shaded winding current, which lags the induced electromotive force, reaches zero, and there is no opposing flux. Therefore the main field flux passes through the shaded portion of the field pole. This results in a weak rotating magnetic field with sufficient torque to start small motors. Because of the low starting torque, shaded-pole motors are furnished in ratings up to approximately 1/25 horsepower and are used with small fans, timing relays, small motion picture projectors, and various control devices. Shaded-pole motors are designed for a specific direction of rotation that cannot be changed after the motor is assembled.
7-15. Split-phase motor. Split-phase motors contain two windings, the main winding and the starting winding. The main winding is wound on the stator and the starting winding is wound on top of the main winding in such a manner that the centers of the poles of the two windings are displaced by 90°. The windings are connected in parallel (fig. 39) to the same supply voltage; therefore, the same voltage is applied to both winding. The starting winding is usually wound with fewer turns of small size wire and has iron on only two sides. It, therefore, has less inductance than the main winding, which has a low resistance and is surrounded by iron on all sides except one. When the same voltage is applied to both windings, the current in the main winding lags the voltage more than the current in the starting winding. This produces a rotating field which starts the motor. As the motor approaches full speed, a centrifugal mechanism mounted on the rotor opens a centrifugal switch (fig. 39) and disconnects the starting winding from the line. If the centrifugal mechanism should fail to open the switch, the motor will run hot because of the high resistance of the starting winding and will burn out the starting winding if allowed to run any length of time. This is the most frequent cause for failure of split-phase motors. The split-phase motors are usually furnished in ratings from 1/60 to 1/3 horsepower and are desirable for use in machine tools, office equipment, pumps, fans, blowers, oil burners, kitchen appliances, and laundry equipment. Split-phase motors may or may not have a built-in thermal overload relay for the protection of the motor during an overload. The relay is usually of the automatic type, opening when the current in the windings is above normal and automatically resetting when the current is restored to normal. To reverse the split-phase motor, reverse the loads of either the starting winding or the running winding.
Figure 39. Schematic of a single-phase, split-phase motor.
7-16. Capacitor-start motor. The capacitor-start motor is so called because a capacitor instead of resistance is used to split the phase. The capacitor, usually mounted on top of the motor, is connected in series with the starting winding to provide the necessary shift in time phase of the current flowing through it. This capacitor is usually intermittently rated and must be disconnected for normal operation, which disconnection is usually done by a centrifugal mechanism mounted on the rotor. When the motor is stopped, the switch closes and is in the correct position when the motor is started again. The capacitor-type motor has a higher starting torque at less current than the split-phase motor and also provides a greater thermal capacity. Capacitor-start motors are usually furnished in ratings from 1/6 to 1 horsepower and are used on compressors, pumps, fans, and machine tools.
7-17. Permanent-split capacitor motor. The permanent-split capacitor motor is similar to the capacitor-start motor, except that the permanent capacitor (fig. 40) is connected in series with the starting winding permanently and is not removed from the circuit during operation by a centrifugal switch. This eliminates the need for a centrifugal switch and switch mechanism. The capacitor is continuously rated and is selected to give best operation at full speed while sacrificing starting torque. Permanent-split-capacitor motors develop 40 to 60 percent starting torque and are used on easily started loads such fans and blowers.
Figure 40. Schematic of a single-phase permanent-split capacitor motor.
7-18. Capacitor-run motor. The capacitor-run motor has two capacitors connected in parallel (fig. 41). One, a running capacitor, is a continuously rated capacitor and remains in the circuit while the motor is running. The other, a starting capacitor, is intermittently rated and is used in the circuit during starting. The starting capacitor is removed by a centrifugal mechanism and switch as the motor approaches full speed. Therefore the capacitor-run motor is a combination of the capacitor-start and the permanent-split capacitor motors. This motor has a high starting torque as well as good running characteristics and is generally furnished in ratings of 1/2 horsepower and larger. Capacitor motors may be reversed by changing the leads to the starting winding at the motor terminals.
Figure 41. Schematic of a single-phase dual voltage capacitor run motor.
7-19. Three-Phase AC Induction Motors. The three-phase ac induction motor is also called a squirrel-cage motor. The rotating magnetic field of the three-phase motor operates the same as a two-phase motor. The difference between a two-phase and a three-phase motor in the windings. The two-phase windings are placed 90° apart where the three-phase windings are placed 120° apart. This means that the currents that produce the magnetic field reach a maximum 1/180 second apart in a 60-cycle circuit.
7-20. Notice figure 42, which shows the connection of a wye-connected stator in a three-phase induction motor. The rotor of the motor is represented by the compass needle, which points in the direction of the magnetic field and revolves as the magnetic field revolves. The individual current waves are shown along the phase wires as they would actually be during operation. Notice the current in phase A reaches a maximum at position 1 and at that instant the currents in phases B and C are both negative.
Figure 42. Three-phase induction motor.
7-21. At position 2, 1/180 second later, the current is at a maximum in phase B and is negative in phases A and C. At position 3, which is 1/180 second later than position 2, the current is at positive maximum in phase C and is negative in phases A and B. In the diagrams the magnetic field caused by the maximum positive current is shown in heavy dark lines. The other poles are indicated with dotted lines. The rotor, like the single-phase motor, follows the rotating magnetic field of the stator winding.
7-22. The speed of the induction motor is always less than the speed of the rotating field of the stator. If the rotor were to turn at the same speed as the rotating field, the rotor conductors would not be cut by any magnetic field and no voltage would be induced in them. No current would flow; thus there would be no magnetic field in the rotor and, hence, no torque.
7-23. A three-phase induction motor exerts a torque when at rest and therefore starts itself when the proper voltage is applied to the stator field coil. To reverse the direction of rotation of a three-phase motor, reverse the leads of any two phases.
7-24. The three-phase spring (wound rotor) induction motor is wound with a three-phase drum winding. The windings are connected wye (y) or delta (wye connection is shown in fig. 43), and the three leads are brought out and connected to three electrical contact rings (sliprings) which are secured to the shaft. Brushes riding on the rings are connected to an external resistance through which the rotor circuit is completed. Motors containing wound rotors have a high starting torque with low starting current us adjustable speed.
Figure 43. Schematic of a three-phase slipring induction motor.
7-25. Synchronous Motors. Synchronous motors are divided into two classes according to their size and application. The larger horsepower motors use three-phase power and have separately excited salient pole rotors. The smaller motors are usually furnished as fractional-horse-power motors and obtain their rotor-excitation current through induction. Although an induction motor is considered as a constant-speed motor, it is subject to approximately 10 percent variation in speed under various load conditions, since the operating torque depends upon the percentage of slip between the rotating magnetic poles and the magnetic flux of the rotor. The speed of a synchronous motor is controlled by the frequency of the alternating-current power source and is, therefore, maintained with a high degree of accuracy. The smaller size synchronous motors are constructed as reluctance motors or hysteresis motors, which are described in following paragraphs.
7.26. Reluctance motor. The stator of a reluctance motor is similar in construction to that of the single-phase induction motor and may be of the shaded-pole, split-phase, or capacitor type. The squirrel-cage rotors have grooves cut to allow the addition of salient poles. The number of salient poles mounted on the rotor corresponds to the number of rotating stator poles. The motor starts as an induction motor, but, upon reaching a speed near synchronism, it pulls into step because of the salient poles and operates at exactly synchronous speed. The reluctance motor, unlike the larger size synchronous motor (which has on the rotor a field winding supplied with direct-current excitation and which operates at unity or at a leading power factor with high efficiency), operates at a lagging power factor and has a rather low efficiency. Therefore, the reluctance motor is used only where exact synchronous speed is required, such as in electric clocks, time switches, relays, and meters.
7-27. Hysteresis motor. The construction of the hysteresis motor is similar to that of the reluctance motor except for the rotor. The rotor does not have a squirrel-cage winding. Instead the rotor core is usually made of a ring of metal having permeability, such as chrome or cobalt steel. The highly magnetic core material retains its magnetism over a period of time and this enables the rotor to reach its synchronous speed. Hysteresis motors develop a constant torque from zero synchronous speed and are used in a clock’s timing devices; they will operate unattended for long periods of time.
7-28. Universal Motors. Universal motors are designed for operation from either direct current or single-phase alternating current and are all of the series-wound type; that is, the field windings are connected in series with the armature windings. Universal motors are divided into two types: the straight series-wound universal motor and the compensated series-wound universal motor.
7-29. Straight series-wound universal motor. The straight series-wound universal motor has the field windings connected in series for opposite polarity, the same as the field winding of any direct-current motor, and then in series with the armature (fig. 44A). This type motor uses salient-type pole pieces (fig. 45) for mounting the field windings and is usually furnished in sizes up to 1/3 horsepower but can be furnished in larger sizes for special applications. The motor full speed is rated from 1800 rpm on the larger sizes to 5000 rpm on the smaller sizes and no-load speeds ranging from 12,000 to 18,000 rpm. Since these motors run at dangerously high speeds at no-load, they are usually built into the equipment being driven. This type motor is used in portable machines and portable equipment in general.
Figure 44. Schematic wiring diagrams of universal motors.
Figure 45. Salient pole laminated steel core of a universal motor.
7-30. Compensated series-wound universal motor. The compensated series-wound, distributed-field, universal motor contains a main winding and a compensating winding connected in series with the armature (fig. 44B). The core of this type motor is similar to the construction of the core of a split-phase alternating-current motor (fig. 46). The main winding is usually placed in the slots first and the compensating winding is placed over it, 90 electrical degrees away. The compensating winding reduces the reactance voltage present in the armature when alternating current is used. It has a better commutation and power factor than does the straight series-wound universal motor, and usually comes in higher horsepower ratings. Compensated series-wound universal motors are used with portable tools, office machines, vacuum-cleaning equipment, and portable equipment in general.
Figure 46. Compensated series-wound universal motor.
8. Motor Maintenance
8-1. Cleanliness is essential if we are to have trouble-free motor operation. Dirt, moisture, and excessive oil tend to restrict air circulation, deteriorate the insulation, and accelerate wear and friction. To increase the life of the motor, you should wipe all excessive dirt, oil, and grease from the surface of the motor. Use a cloth moistened with a recommended cleaning solvent.
CAUTION: Do not use flammable or toxic solvents for cleaning, as they may cause injury to personnel or damage to property.
8-2. The inside of the motor can be cleaned with a blower or with compressed air. Care should be exercised when using compressed air so the insulation is not damaged by the blast of air.
8-3. Motor Lubrication. You must be sure the motor has been properly lubricated. Lubrication should be done according to the applicable publication for the motor.
8-4. You should also make periodic checks for grease or oil leakage and for overlubrication. After lubricating a motor, be sure to wipe away any excess oil or grease.
8-5. Wiring. The wiring leads to the motor must be kept clean and secure and checked for wear. If the wiring becomes frayed, it must be replaced.
8-6. Mounting. Motors must be kept secure to perform efficiently. A loose mounting can cause a belt to slip and wear or can cause vibrations which tend to harden any copper component (wiring and tubing).
9. Circuit Protective and Control Devices
9-1. Electricity, when properly controlled, is of vital importance to the operation of refrigeration equipment. When it is not properly controlled, however, it can become dangerous and destructive. It can destroy components or the complete unit; it can injure personnel and even cause their death.
9-2. It is of the greatest importance, then, that we take all precautions necessary to protect the electrical circuits and units and that we keep this force under proper control at all times. In this section we shall discuss some of the devices that have been developed to protect and control electrical circuits.
9-3. Protective Devices. When a piece of equipment is built, the greatest care is taken to insure that each separate electrical circuit is fully insulated from all others so the current in a circuit will follow its intended individual path. Once the equipment is put into service, however, there are many things that can happen to alter the original circuitry. Some of these changes can cause serious troubles if they are not detected and corrected in time.
9-4. Perhaps the most serious trouble we can find in a circuit is a direct short. You have learned that the term is used to describe a situation in which some point in the circuit, where full system voltage is present, comes in direct contact with the ground or negative side of the circuit. This establishes for current flow a path that contains no resistance other than that in the wire carrying the current, and these wires have very little resistance.
9-5. You will recall that, according to Ohm's law, if the resistance in a circuit is extremely small, the current will be extremely great. When a direct short occurs, then there will be an extremely heavy current flowing through the wires.
9-6. To protect electrical systems from damage and failure caused by excessive current, several kinds of protective devices are installed in the systems. Fuses, circuit breakers, and thermal protectors are used for this purpose.
9-7. Circuit protective devices, as the name implies, all have a common purpose: to protect the unit and the wires in the circuit. Some are designed primarily to protect the wiring. These open the circuit in such a way as to stop the current flow when the current become greater than the wires can safely carry. Other devices protect a unit in the circuit by stopping current flow to it when the unit becomes excessively warm.
9-8. Control Devices. The components in an electrical circuit are not all intended to operate continuously or automatically. Most of them are meant to operate at certain times, under certain conditions, to perform very definite functions. There must be some means of controlling their operation. Either a switch or a relay, or both, may be included in the circuit for this purpose.
9-9. Switches. Switches are used to control the current flow in most electrical circuits. A switch is used to start, to stop, or to change the direction of the current flow in the circuit. The switch in each circuit must be able to carry the normal current of the circuit and must be insulated heavily enough for the voltage of the circuit.
9-10. The toggle switch (as shown in fig. 47 along with the knife switch which is used to simplify the operation of a toggle switch) is used more than any other kind of switch, but there are others, such as pushbutton, microswitch, rotary selector, and even relays and magnetic motor starts, which can be classified as switches since they operate, start, and stop current flow in a circuit.
Figure 47. Various knife and toggle switches.
9-11. Magnetic motor starters. A magnetic motor starter is wired to satisfy a particular application; and there are numerous applications, so we will not attempt to cover all of them. Figure 48 shows a pump, air conditioner, and fan operating through motor starters. Look at figure 48 and notice the two single-pole single throw (SPST) switches, thermostat, holding coils, motor protectors, and step-down transformer. Also notice that three-phase equipment must have protective devices in at least two wires, but single-phase equipment may be protected by one protective device.
Figure 48. Use of magnetic motor starters.
9-12. In figure 48, the air conditioner will not operate unless the fan and pump holding coils are energized, and the thermostat switch is closed. Notice that the control circuit for the air conditioner is wired in series through the auxiliary contacts of the fan and pump motor starters. Also, notice that a low voltage may be used to control a higher voltage with the use of a step-down transformer.
9-13. If switches Nos. 1 and 2 are closed, the pump and fan will operate but the air conditioner will not until the thermostat completes the circuit for its holding coil. If an overload develops in the pump or fan, the heaters open the respective control circuit, which in turn breaks the control circuit for the air conditioner.
9-14. Maintenance and Troubleshooting. Most of the troubles in motor starters will be in the load contacts, holding coil, or heaters. A voltmeter can be used to check the load contacts, if the voltmeter leads are connected in parallel to each set of contacts and the holding coil is energized. The voltmeter should read zero. If it does not, then the contacts need to be cleaned or replaced. With power off, the heaters and the holding coil may be checked with the ohmmeter. Heaters should be sized correctly to give protection to the motor; if undersized they would cause nuisance tripping in normal current flow.
9-15. In this chapter you have studied the fundamentals of electricity, circuits, Ohm's law, transformers, magnetism, electrical meters, circuit protective and control devices, and motors that are used to drive refrigeration equipment. Let's continue with another type of drive for refrigeration equipment, the gasoline engine.