Section 5-3 - Operations on the Tibia 5-18. INTRAMEDULLARY PINNING FOR TIBIAL FRACTUREThis procedure involves the insertion of a nail through a short incision made over the anterior aspect of the tibia and medial to the tibial tubercle. Proper alignment and apposition are quite important to the success of this operation, as well as an accurate fit in the medullary canal. This method obviates the need for plates. Operating Room Preparation.
Patient Preparation.
Operative Procedure.
5-19. OPERATION FOR TIBIAL SHAFT FRACTUREFor simple transverse fractures and many oblique fractures, the fragments are reduced by external manipulation and the leg encased in a plaster cast. For severely fragmented fractures, skeletal traction or the insertion of an appropriate appliance may be used. Usually, these fractures are at the lower and middle thirds of the tibial shaft and at the junction of these two thirds. The fractures that result from a direct blow often are the transverse or comminuted types, whereas those that result from a twisting force are the spiral type. OR Preparation.
Patient Preparation.
d. Operative Procedures. This is the same as in paragraph 5-9c.
5-20. COMPRESSION PLATING OF FRACTURES (SEE FIGURE 5-5)The use of compression in achieving fixation and promoting union in cancellous bone is now well accepted. This plate relies on the mechanical compression prior to fixation for its function. It provides rigid fixation not only because of the compression, but also because it is a very thick, heavy plate. The advantages of compression are the fixation is more rigid, the gap between the fragments that must be bridged by new bone is narrowed, and the external immobilization required after surgery is reduced or may even be eliminated.
Figure 5-5. Compression plating of fractures.
b. Operating Room Preparation. The basic orthopedic instrument setup is needed, with the addition of the compression plating set. Several instrument companies manufacture various types of compression instruments and implant systems. The purpose of such a system is to approximate the bone fragments under compression during the act of applying an appliance for rigid fixation. c. Patient Preparation. Positioning and preparation of the patient depends on the fracture site. d. Operating Procedure. After the fracture has been reduced, the proper plate and screws are selected. The periosteum is stripped in preparation for plating. (1) To attach one end of the plate to the bone, the plate is centered over the fracture. Holes are drilled in proximal fragment using a hand-held drill guide. After the hole is drilled, a self-tapping screw is placed. (If the surgeon prefers, a separate tapping instrument is included in the set.) (2) The plate is affixed to the proximal end with necessary screws. A locator drill guide hook is placed in the elongated slot on the distal end of the plate and an anchor hole is drilled. A Trinkle handle is provided which can be snapped to the locator drill guide. (3) With compression clamp capstan handle in free position, the compress-ion clamp foot is placed over the anchor hole. The anchor screw is inserted. The handles are pivoted toward the anchor screw and the compression clamp hook is engaged into the slot on the distal end of the plate. Capstan handles are locked across the compression clamp. Compression is applied by turning the capstan handle knob clockwise. (4) All remaining bone screws are then placed with full compression applied. Compression is then released by swinging the capstan handle to a free position. The anchor screw and compression clamp are removed. (5) The wound is closed in the routine manner. The affected limb may or may not be placed in a plaster cast. |